• Envirograf Intumescent Material ES/MP

Envirograf Intumescent Material & Paneled Door Upgrade

Product 38

Unfortunately, we no longer stock this product. Thermoguard Timbercoat Door Upgrade System may be a great alternative to consider, however you must contact us to confirm suitability prior to purchase/use.

Please contact our technical team on 0113 2455450 (option 2) or send a message to [email protected] to confirm suitability for your project and get 10% off.

Quantity

Description

The Envirograf Intumescent Material & Paneled Door Upgrade system comprises of intumescent cloth, with many options of facings, for upgrading flat panelled doors to fire-rated doors. Intumescent Flat Panelled Door Upgrade Kits are also available for creating fire doors out of new or existing doors, consisting of the correct materials and adhesives needed.

Available with white, 1mm-thick fireproof card that must be painted with spirit-based undercoat and topcoat (Product 42), the veneer may be painted or varnished after fitting with Envirograf Acrylic Thixotropic Adhesive (Ref: IA - Intumescent Adhesive), in accordance with the guidelines in our download section, and advice from our technical team on 0113 2455450 (option 2) or [email protected].



Advantages


  • Intumescent cloth can be applied to existing panelled doors in order to upgrade them to up to 30 minute fire doors.
  • Intumescent cloth can also be used between 6mm plywood panels if new doors are being made, giving up to 30 minutes of fire protection.
  • Used in conjunction with Product 42, this system can upgrade new or old standard doors to give them up to a 60-minute fire rating
  • Fireproof card face is available in standard white, faced with Gaboon or birch ply, or in a range of veneers



Ordering References


Click To Jump To Product:




Use when "cutting" into grooves:


Ref Size Order Details
ES/MULTI 1220mm wide Priced per square metre



For making new panelled doors:


Ref Size Order Details
ES/MP 1220mm wide Priced per linear metre



Faced with white fire protection card (for painting):


1mm-thick card that must be painted using a spirit based topcoat or undercoat (Product 42)

Rolls:

Ref Size Order Details
ES/MP/900 900mm wide On a roll (priced per linear metre)



Sheets:

Ref Size Order Details
ES/MP/FC3/2 1000mm x 1220mm sheet minimum 20 sheets per order
ES/MP/FC3/3 1220mm x 2000mm sheet minimum 20 sheets per order



Faced with ply or wood veneer (for varnishing):


Ref Description Size
ES/MP/GP with Gaboon ply facing 1200 x 1200mm
ES/MP/FC3/3 1220mm x 2000mm sheet 1200 x 1200mm
ES/MP/V Veneered sheet (Ash) 1200 x 1200mm
ES/MP/V Veneered sheet (White Oak) 1200 x 1200mm
ES/MP/V Veneered sheet (Pine) 1200 x 1200mm
ES/MP/V Veneered sheet (Sapele) 1200 x 1200mm
ES/MP/PLY with 1.8mm birch ply facing (stripped doors) 1500 x 1500mm sheet



Upgrade Kits


Intumescent Flat Panelled Door Upgrade Kits for creating fire doors out of new or existing doors, consisting of the correct materials and adhesives needed.



ES/MP/DK2C - White


Finishes: Satin/Matt/Gloss

Contains:

  • 900mm x 1350mm Material/Fire Card
  • 75ml Stabond
  • 250ml HW04S
  • 2 x 310ml tube IA adhesive
  • 500ml HW01F
  • 500ml HW04 Premier



ES/MP/DK2O - Oak


Finishes: Satin/Matt

Contains:

  • 1200mm x 1200 mm Oak Veneer
  • 75ml Stabond
  • 250ml primer
  • 2 x 310ml tube IA adhesive
  • 333ml HW02N Clear 250ml
  • HW03 Premier



ES/MP/DK2P - Pine


Finishes: Satin/Matt

Contains:

  • 1200mm x 1200 mm Pine Veneer
  • 75ml Stabond
  • 250ml primer
  • 2 x 310ml tube IA adhesive
  • 333ml HW02N Clear
  • 250ml HW03 Premier



ES/MP/DK3 - Gaboon


Finishes: Satin/Matt

Contains:

  • 1200mm x 1200mm Gaboon Plywood
  • 75ml Stabond
  • 250ml primer
  • 620ml TCA adhesive
  • 333ml HW02N Clear
  • 250ml HW03 Premier



Made to order:


Please contact our sales team on 0113 2455450 or [email protected] for availability.

Ref Description Size
ES/MP/V Veneered sheet (Cherry) 1200 x 1200mm
ES/MP/V Veneered sheet (White Beech) 1200 x 1200mm



Adhesives:


  • TCA - Thixotropic Contact Adhesive
  • IA - Intumescent Adhesive



Application


Refer to the data sheets in the attachments section above for more and further information.



Material Specification:


Multigraf Intumescent material chemical constitution

  • Mineral Wool Fibre 20-70% by weight
  • Exfoliating Graphite 20-60% by weight
  • Organic Binder (including adhesive coating) 5.0-30% by weight



Test Details:


Integrity Insulation
Chiltern RF04083 51 Minutes 51 Minutes
Chiltern RF02059 34 Minutes 30 Minutes



Click to go back to the top of the page

IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

Any Envirograf products to be used in or for Harrods department store should be authorised with our Technical Team prior to purchase.

Product Details
Product 38
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


questions James on 2020-06-23 14:57:40
Question: 

Does the card get applied to one side of the door or both sides?

Answer: 

The card can be applied to one or both sides of the door, please confirm with Building Control if one or both sides are required to be protected.


Question about the product

* Required fields
(read)