• Envirograf Rainscreen Fast Fix Cavity Barrier
  • Envirograf Rainscreen Fast Fix Cavity Barrier
  • Envirograf Rainscreen Fast Fix Cavity Barrier
  • Envirograf Rainscreen Fast Fix Cavity Barrier

Envirograf Rainscreen Fast Fix Cavity Barriers

Product 55 - RS/FFCB

We no longer stock this product, but can recommend Tenmat VFB Plus Ventilated Fire Barrier as our nearest alternative. Please contact our Technical Team on 0113 2455450 (option 2) or send a message to [email protected] prior to purchase/use for advice on suitability.

Quantity

Description

Rainscreen Fast Fix Cavity Barriers leave a continuous gap for airflow in rainscreen cavities, with intumescent strips that, in the event of fire, expand to seal ventilation gaps.

  • Refer to sizes below
    • Ref-code/25 only available in 25mm, and Ref-code/40 in 40mm airflow gap sizes
  • Very simple installation
  • 1220mm lengths
  • Supplied with brackets
  • For vertical & horizontal fixings



Sizes:

Supplied in 1220mm lengths, colour-coded with white pins for a 25mm airflow gap and red pins for a 40mm airflow gap.

25mm Airflow Gap (white pins)

Ref Cavity Width Width Thickness Airflow Gap
RS/FFCB/50/25 75mm 50mm 60mm 25mm
RS/FFCB/60/25 85mm 60mm 60mm 25mm
RS/FFCB/75/25 100mm 75mm 60mm 25mm
RS/FFCB/100/25 125mm 100mm 60mm 25mm
RS/FFCB/150/25 175mm 150mm 60mm 25mm
RS/FFCB/175/25 200mm 175mm 60mm 25mm
RS/FFCB/200/25 225mm 200mm 60mm 25mm
RS/FFCB/225/25 250mm 225mm 60mm 25mm
RS/FFCB/250/25 275mm 250mm 60mm 25mm
RS/FFCB/275/25 300mm 275mm 60mm 25mm

40mm Airflow Gap (red pins)

Ref Cavity Width Width Thickness Airflow Gap
RS/FFCB/50/40 90mm 50mm 60mm 40mm
RS/FFCB/60/40 100mm 60mm 60mm 40mm
RS/FFCB/75/40 115mm 75mm 60mm 40mm
RS/FFCB/100/40 140mm 100mm 60mm 40mm
RS/FFCB/150/40 190mm 150mm 60mm 40mm
RS/FFCB/175/40 215mm 175mm 60mm 40mm
RS/FFCB/200/40 240mm 200mm 60mm 40mm
RS/FFCB/225/40 265mm 225mm 60mm 40mm
RS/FFCB/250/40 290mm 250mm 60mm 40mm
RS/FFCB/275/40 315mm 275mm 60mm 40mm

Envirograf Rainscreen Fast Fix Cavity Barriers allow airflow through rainscreens and cladding systems, sealing up in the event of fire to protect buildings from spreading flames and smoke. Both sides of the rock-fibre barrier are coated with intumescent material, whilst the airflow side is fitted with an intumescent strip that expands to cover the airflow gap, up to the external wall.

The cavity barriers are 1220mm in length and are supplied with fitting brackets, 3 per length.

Application

Suitable for both horizontal and vertical applications. The fixing brackets supplied need to be mechanically fixed to the substrate using non-combustible fixings. Fit the brackets at 500mm centres then push the lengths of barrier onto the brackets ensuring they are centred in the middle of the barrier and that the barrier is pushed fully back against the substrate. When fitting the barriers ensure that the brown-faced intumescent strip is facing forward. Note: the intumescent strip is colour-coded with white pins for a 25mm airflow gap and red pins for a 40mm airflow gap.

Test Details:

Chiltern International Fire IF11057 to BS EN 1363-1: 1999

Envirograf Fire Cavity Barriers should be fitted by experienced professionals to ensure they are installed correctly. Products can only be guaranteed by Envirograf if fitted correctly and incorrect installations will be condemned if inspected. Check labels, fixing brackets, manufacturer installation instructions, etc. Should a site visit be required to check installation, this can be arranged upon request but will be chargeable.

IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and ConditionsWe will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

Any Envirograf products to be used in or for Harrods department store should be authorised with our Technical Team prior to purchase.

Product Details
Product 55 - RS/FFCB
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.