Thermoguard Wallcoat BS Class 1/0 & EN Class B System is a coloured fire retardant paint system for interior plasterboard ceiling and wall surfaces. Each pack contains the correct amount of basecoat (Wallcoat Insulating Basecoat) and topcoat (Wallcoat Smoke & Flame Retardant Topcoat) to ensure protection is achieved inline with the manufacturers recommendations to the respective area in question.
Thermoguard Wallcoat BS Class 1/0 & EN Class B System
Thermoguard Wallcoat BS Class 1/0 & EN Class B System is a coloured fire retardant paint system for interior plasterboard ceiling and wall surfaces. These packs have been created to help users ensure they are purchasing sufficient product for their project. Each pack contains the correct amount of basecoat (Wallcoat) and topcoat (Wallcoat Smoke & Flame Retardant Topcoat) to ensure protection is achieved inline with the manufacturers recommendations to the respective area in question.
4000+ colours available from RAL, BS & NCS
Each component of the packs can still be purchased individually if required here: Wallcoat Insulating Basecoat and here: Thermoguard Wallcoat Smoke & Flame Retardant Topcoat
Pack Contents
Specification (Interior Use Only)
Inspect and prepare in accordance with manufacturer’s instructions and apply -
2 coats of Thermoguard Wallcoat Smoke & Flame Retardant Topcoat may be required for strong/dark colours - Thermoguard Wallcoat will be provided in a suitable undercoat shade to aid topcoat opacity unless instructed otherwise.
For 30 & 60 minute protection please see Thermoguard Wallcoat 30 & 60 Minute Protection System Packs
Fire Testing & Certification
Tested at UKAS Fire Test Laboratory -
Thermoguard issue a Fire Certificate upon request for each correctly specified project for Insurance, Fire and Building Authority and Client Records against proof of purchase. Certified Fire protection is guaranteed if all instructions are followed on suitable surfaces.
Preparation
Surfaces should be sound and firmly adhering, clean, dry and free of surface contamination. Remove loose, flaking or suspect paint films and adequately abrade existing smooth or hard coatings – abrasion not needed on Vinyl Matt.
Application & Conditions
Apply by brush or roller, thinning to a maximum 5% with water, provided specified spread rate is achieved. Maintain wet edge during application.
During application and drying, ensure a minimum temperature of 5°C, maximum relative humidity 75% and surface temperature at least 3°C above dew point. Avoid condensation.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.
![]() | Question:
with thermoguard wall coat can you achive 60min protection and how many coats would you need on exsiting plasterboard |
Answer from Rawlins’ Technical Team:
This kit will only achieve Class 0 level of fire protection. Assuming the substrate meets the minimum requirements, it is clean, dry, sound and prepared as detailed in the Technical data Sheet we can recommend Thermoguard Wallcoat 30 & 60 Minute System for Plasterboard. Building Control approval should be sought prior to purchase and application. 3 coats of Wallcoat and at least 1 coat of Topcoat would be required. | |
![]() | Question:
Is Thermoguard overpaintable with emulsion? I need to improve the rating of one area of ceiling and want it to look the same as the rest of the room. |
Answer from Rawlins’ Technical Team:
Yes. Once the FULL Thermoguard system has been applied, this can be overcoated with your own water based emulsion as long as Thermoguard Flame Retardant Additive is added to your product of choice before use. | |
![]() | Question: Can Thermoguard wallcoat basecoat and smoke and flame retardant topcoat be applied to previously painted polystyrene ceiling tiles as a suitable intumescent application? |
Answer from Rawlins’ Technical Team: No, unfortunately we don't have a system for polystyrene ceiling tiles. | |
![]() | Question: Can Thermoguard wall coat be applied over existing paint, in this case matt white emulsion on intumescent plasterboard, just applied and now told we need fire retardant paint.
Heritage train shed workshop.
Thanks |
Answer from Rawlins’ Technical Team: Yes, Thermoguard Wallcoat can be applied over normal, decorative paints (not other fire retardants). Surfaces should be sound and firmly adhering, clean, dry and free of surface contamination. Remove loose, flaking or suspect paint film and adequately abrade existing smooth or hard coatings – abrasion not needed on Vinyl Matt. | |
Thermoguard Wallcoat Smoke & Flame Retardant Topcoat is a fire-retardant paint for walls and ceilings. Works in combination with Thermoguard Wallcoat Insulating Basecoat Controls surface spread of flame and fire propagation Interior & exterior use Controls smoke and flaming droplets/particulates to BS EN Class B s1 d0 (as part of...
Thermoguard Wallcoat 30 & 60 Minute System for Plasterboard is a coloured intumescent paint system for interior plasterboard and cement board ceiling and wall surfaces. These packs have been created to help users ensure they are purchasing sufficient product for their project. Each pack contains the correct amount of basecoat (Wallcoat)...
Thermoguard Wallcoat Insulating Basecoat is an intumescent basecoat (part of a complete system) to upgrade potentially dangerous ‘multi-layer’ - previously painted - walls & ceilings in communal areas: Controls surface spread of flame and fire propagation to Class 0 & EN Class B Achieves EU and new British safety standards on walls...