    Thermoguard Sprayshop Lacquer Topcoat is a hard, wear-resistant Fire Protection AC lacquer for application by professional lacquer sprayers in spraybooths, for wood fire protection.

    Provides intumescent fire protection (Class B s2 dO + Class O); when exposed to fire, Thermoguard Fire Varnish expands to create an insulating barrier, protecting timber surfaces from flames, heat and oxygen and suppressing emission of deadly smoke & gasses.

    Transparent Wood Stains

    Representations shown below; represented as solid colours in the colour picker further above.



    Features & Benefits


    • Available in woodshades and 350+ colours from RAL and BS
      • Satin and Matt finishes
      • 80m² pack size
    • Wood fire protection
    • Interior projects only
    • Class B s2 dO + Class O
    • Hard, wear-resistant
    • For application by professional lacquer sprayers in spraybooths
    • Intumescent fire protection
    • Expands to create an insulating barrier
      • Protects timber surfaces from flames, heat and oxygen
      • Suppresses emission of deadly smoke & gasses
    • Quality assurance - Manufactured under ISO 9000
    • Use with Thermoguard Sprayshop Lacquer Topcoat Thinners - a special blend of solvents specifically designed to dilute Thermoguard Sprayshop Lacquer Topcoat if necessary for application
      • Also ideally suited for cleaning equipment or splashes after use of Thermoguard Sprayshop Lacquer Topcoat

     



    Application


    Basecoat

    • 1 spray coat @ 150 microns wet, 75 microns dft. Leave 36+ hrs in good drying conditions. When hard dry apply:

     

    Sprayshop Lacquer

    • 1 spray coat @ 60 microns wet, 30 mirons dft.
      • For Colours, Woodshades or wear areas 2nd coat after 2 > 36 hrs
    • If 36+ hrs delay before 2nd coat, abrade to remove gloss & leave overnight to condition before applying 2nd coat.

     

    Equipment

    • Conventional pressure pot & gun (best) 5 > 10% Thinners.
    • Airless - 11 thou tip. thin 0 > 5% Thinners.
    • Avoid solvent contamination of basecoat or water/basecoat contamination.



    Fire Test Standards


    In UKAS-accredited Fire Test laboratory

    • BS EN Class B s2 dO
      • See section below for New Fire Regulations & Tests Explained
    • 4 Class O
      • Class 0 includes Class 1

    Note -



    Fire Certification


    A Certificate of Supply can be issued upon request for each correctly specified project for Insurance, Fire and Building Control Authority and Client Records against proof of purchase.



    Conditions


    During application & drying of the full system

    • Ensure surfaces are thoroughly dry – max 18% moisture content.
    • Maximum relative humidity RH 75%. Ensure adequate ventilation.
    • Minimum air temperature 6°C. Minimum surface temperature 3°C above dewpoint– avoid condensation.



    New Fire Regulations & Tests Explained


    • The new fire standard BS EN test lasts 20 mins. with airflow replaces the old BS 476 tests which lasted 10 mins and strangely restricted airflow.
    • The new standard for flamespread and heat release Class B replaces Class O.

    The new BS EN tests also monitor -

    • Smoke & Gas “s” – s1 + s2 are none or very low & compliant, s3 = moderate smoke, s4 = heavy smoke.
    • Flaming Droplets or Airborne particulates – dO is none, d1 = low, d2 = moderate d3 = high levels.



    Quality Assurance


    All products are manufactured under ISO 9000.

    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

    Product Details
    HG2240

    Data sheet

    Manufacturer
    Thermoguard
    Parts
    Two
    Base Type
    Solvent
    Interior/Exterior Use
    -
    Solvent
    Lacquer
    Suitable Substrates
    Wood/timber
    Level of Protection
    Class B s2 dO + Class O
    Key Features
    -
    Application
    Spray
    Dry to Recoat (at 20°C)
    2 hours
    Coverage
    80 sq m
    Recommended Thinner/Cleaner
    -
    Compatible Primers
    -
    Compatible Topcoats
    -
    Max. Application Temperature
    -
    Min. Application Temperature
    6°C
    Density
    -
    Solids by Volume
    -
    VOC
    -
    Shelf Life (from date of manufacture)
    -
    Dry for Topcoat (at +20°C)
    -
    UN Number (Activator)
    UN2924
    UN Number (Base)
    UN1263
    Brand
    Thermoguard
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Thermoguard Sprayshop Lacquer Topcoat is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT


    You might also like

    Thermoguard Fire Varnish Basecoat

    A clear intumescent varnish that is the first coat of a 2 coat system (3 coats externally) for the decorative Fire Protection of timber and timber derived substrates to BS Class 1, Class 0 and EN Class B s2 d0. See Thermoguard Fire Varnish Overcoat (Interior) or Thermoguard Fire Varnish Overcoat (Exterior) to complete the system. Complete...

    Price £120.75 (ex. VAT)

    £144.90 (incl. VAT)

    £120.75 (ex. VAT)

    In Stock and Available for Delivery

    Thermoguard Professional Lacquer Topcoat Thinner

    We no longer stock this product; please contact our technical team on 0113 2455450 (option 2) or send a message to [email protected] where we will be happy to find an alternative product. Thermoguard Professional Lacquer Topcoat Thinners are a special blend of solvents specifically designed to dilute Thermoguard Sprayshop Lacquer...

    In stock

    Thermoguard Professional Lacquer Topcoat

    We no longer stock this product; please contact our technical team on 0113 2455450 (option 2) or send a message to [email protected] where we will be happy to find an alternative product. Thermoguard Professional Lacquer Topcoat, a hard, wear resistant Fire Protection AC lacquer for application by professionals using brush, roller...

    In stock