Thermoguard Wallcoat Anti-Microbial BS Class 1/0 & EN Class B System, containing correct quantities of Thermoguard Wallcoat Insulating Basecoat and Thermoguard Wallcoat Anti-Microbial SFR for 25m2 and 100m2 coverage respectively. Protects walls and ceilings covered with Wallpaper, Multi-Layer Paints (no number-of-coats limit), Asbestos or Antimony-paint contamination.

  • Upgrades Multi-Layer paints to BS EN Class B s1 d0 + Class 0
  • Safest flamespread standards Class 0 and new Class B, toxic smoke and gas standard s1, flaming droplets standard d0
  • Enables property managers to meet Duty of Care in just 2 coats
  • 91.5% Corona virus reduction in just 2 hrs
  • 87.5% Corona virus reduction relative to biociode treated paints which are themselves 99.9% effective to bacteria
  • 99.9% bacteria reduction in 24 hrs to ISO 22196
  • Contains CORONA-KILL
  • 4000+ colours available from RAL, BS, NCS & Thermoguard Select colour range
  • Please note that Wallcoat Insulating Basecoat will be provided in a suitable undercoat shade to aid topcoat opacity

Please note: Colours are sold in the nearest tin size but actual paint volume per tin may vary up to 10% depending on colour.

**Available for delivery - see Delivery Options below**

Product customisation

Don't forget to save your customization to be able to add to cart
  • 250 char. max
Colour Group
Size
Finish
£86.30
VAT excluded

£103.56 Tax incl.
Quantity

Description

Thermoguard Wallcoat Anti-Microbial BS Class 1/0 & EN Class B System, containing correct quantities of Thermoguard Wallcoat Insulating Basecoat and Thermoguard Wallcoat Anti-Microbial SFR for 25m2 and 100m2 coverage respectively.

Protects walls & ceilings covered with Wallpaper, Multi-Layer Paints (no number-of-coats limit), Asbestos or Antimony-paint contamination.

4000+ colours available to choose from in RAL, BS and NCS ranges. Also available are 100 Thermoguard Select shades with LRV (Light Reflectance Values).

  • Safest flamespread standards Class 0 & new Class B
  • Safest toxic smoke & gas standard s1
  • Safest flaming droplets standard d0
  • Enables property managers to meet Duty of Care in just 2 coats

Coronaviruses, and Flu viruses can make painted walls and wood contagious for one or more weeks. Bacteria can breed and colonise on painted walls and wood.

Walls protected by Thermoguard Anti-Microbial SFR products rapidly accelerate the death of Corona & Flu viruses, help prevent bacteria colonisation and eradication of harmful bacteria.

Multiple coats of different paint types and brands can cause a flamespread risk as well as wood. Insulation foam installed in modern buildings has been revealed to be highly flammable and release cyanide gas, making control of flamespread more important than ever. Painted walls can harbour and cause spread of dangerous bacteria, fungal & other infections.

British Class 0 is superseded by BS EN Class B s1 d0, protecting from toxic gases & smoke as well as flamespread.

For years common Flame Retardant Paints contained Timonox Antimony, which releases lethal antimony-chloride gas. Thermoguard Anti-Microbial SFR products protect against all of these risks.

 

System Pack Contents

Specification Contents
25m² 1 x 25m² Thermoguard Wallcoat Insulating Basecoat
1 x 25m² Thermoguard Wallcoat Anti-Microbial SFR  (matt or satin)
100m² 1 x 100m² Thermoguard Wallcoat Insulating Basecoat
1 x 100m² Thermoguard Wallcoat Anti-Microbial SFR (matt or satin)



Quick Links - Click To Jump To Section:




Features & Benefits


  • Basecoat and topcoat in one pack
  • Protects walls & ceilings covered with Wallpaper, Multi-Layer Paints (no number-of-coats limit), Asbestos or Antimony-paint contamination
  • Safest flamespread standards Class 0 & new Class B
  • Safest toxic smoke & gas standard s1
  • Safest flaming droplets standard d0
  • Enables property managers to meet Duty of Care in just 2 coats
  • Upgrades Multi-Layer paints to BS EN Class B s1 d0 + Class 0
  • Corona Viruses & Bacteria killed fast after they land on walls or wood protected with Thermoguard’s Anti-Microbial products
  • 91.5% Corona virus reduction in just 2 hrs
  • 87.5% Corona virus reduction relative to biociode treated paints which are themselves 99.9% effective to bacteria
  • 99.9% bacteria reduction in 24 hrs to ISO 22196
  • Contains CORONA-KILL
  • 4000+ colours available from RAL, BS, NCS & Thermoguard Select colour range



LRV Explained


What is LRV?

Light Reflectance Value is the acronym referring to the lightness and darkness of colours, running on a scale from 0% to 100% that increases with the light in a colour.

LRV is commonly confused with "intensity", which actually refers to how vivid or dull a colour is.

Why is LRV important?

LRV is vital for contractors and designers working with care homes, hospitals and other healthcare facilities used by patients suffering from colour blindness, visual impairments or dementia. Using colours that are distinct from another will help aid navigation and can improve mood.

Using clear and high level contrasting colours will help patients distinguish between walls and ceilings, seating, doors and other surfaces. The best way to measure contrast is with the LRV, with at least 30 point difference between colours on adjoining surfaces, helping meet legal requirements of the Equality Act 2010.



Fire & Anti-Microbial Test Performance


At UKAS / EGOLF approved Fire Test Laboratory

Fire:

  • BS EN Class B s1 d0 and Class 0

Bacteria:

Kills Corona Viruses & Bacteria fast after they land on walls or wood protected with Thermoguard Anti-Microbial SFR products.

Test & Results from approved Microbiology virus test lab to ISO 21702:

  • 91.5% Corona virus reduction in just 2 hrs. 87.5% Corona virus reduction relative to biociode treated paints which are themselves 99.9% effective to bacteria
  • 99.9% bacteria reduction in 24 hrs to ISO22196
  • Contains CORONA-KILL®



Application


  • 1 coat Thermoguard Wallcoat Insulating Basecoat
  • 1 coat Thermoguard Wallcoat Anti-Microbial SFR (2 coats for poor opacity colours or textured walls)



Preparation & Application


  • Surfaces should be sound and firmly adhering, clean, dry and free of surface contamination
  • Remove loose, flaking or suspect paint film and adequately abrade existing smooth or hard coatings
  • Apply by brush, dense short-pile roller or spray
  • Maintain wet edge during application



Application Conditions


  • Min. 5°C
  • Max RH 75%
  • Surface 3+°C above dew point
  • Avoid condensation



Specification


  • 1 coat Thermoguard Wallcoat Insulating Basecoat
  • 1 coat Thermoguard Wallcoat Anti-Microbial SFR

Contractor to provide Thermoguard Fire Certificate confirming Wallcoat Anti-Microbial BS Class 1/0 & EN Class B System applied to surface area in sqm on the named building upon completion.



New EU/BS EN Fire Standards Explained


  • BS EN Class B replaces Class 0
  • Today both Class 0 and Class B comply for escape routes, but Class 0 is being phased out
  • New BS EN also protects from toxic smoke – safe ones are s1 and s2.
  • New BS EN also protects from flaming droplets – safest d0
  • New compliant standards for corridors, stairs, lobbies are BS EN Class B s1 d0 and Class B s2 d0



Quality Assurance


Thermoguard products are manufactured under ISO 9000.



Environmental, Health & Safety


Thermoguard Anti-Microbial Smoke and Flame Retardants are water-based low odour, low VoC, user and eco-friendly. Complies with Biocidal Products Directive



IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and ConditionsWe will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

Product Details
WCBSSSYS

Data sheet

Manufacturer
Thermoguard
Application Method
brush, roller, spray
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


Be the first to ask a question about this product!


Question about the product

* Required fields
(read)
Send
You might also like

Thermoguard Wallcoat Insulating Basecoat

Thermoguard Wallcoat Insulating Basecoat is an intumescent basecoat (part of a complete system) to upgrade potentially dangerous ‘multi-layer’ - previously painted - walls & ceilings in communal areas: Controls surface spread of flame and fire propagation to Class 0 & EN Class B Achieves EU and new British safety standards on walls...

Price £43.15
In stock

Thermoguard Wallcoat Anti-Microbial SFR

Thermoguard Wallcoat Anti-Microbial SFR, used with Thermoguard Wallcoat Insulating Basecoat to protect walls and ceilings covered with Wallpaper, Multi-Layer Paints (no number-of-coats limit), Asbestos or Antimony-paint contamination. Upgrades Multi-Layer paints to BS EN Class B s1 d0 + Class 0 Safest flamespread standards Class 0 &...

Price £43.15
In stock