Nullifire (Firetherm) FJ400 Intuspan, a very pliable intumescent expansion joint with a high level of movement that is suitable for gaps up to 100 mm, providing up to 2 hours fire performance with no adhesive required in most situations.
Ideal for high vibration areas, such as lift shaft interfaces
Can accommodate regular cycles of high or low amplitude movement
Tolerates very large movements
Unaffected by moisture
Easy to install using finger pressure even in uneven gaps
Suits vertical & horizontal joints, and head of walls
Nullifire FJ400 Intuspan is a very pliable expansion joint filler, factory applied with a revolutionary 102-times volume expansion intumescent compound. This sandwich of intumescent strip consists of a modified rubber base filled with graphite and combustion modified foam, providing a soft seal and high level of movement that is suitable for gaps up to 100 mm, with up to 2 hours fire performance with no adhesive required in most situations.
It is tolerant of very large movement and is used in areas where standard mastic joints are not suitable, such as large gaps over 35 mm, acoustic isolation joints and areas subject to regular cycles of expansion and contraction or vibration, both in compression and shear, where reliability is vital. In addition, Intuspan is particularly suitable for buildings being designed for earthquake zones or military buildings designed to withstand high ground movement shockwaves. All joints should be designed to BS 6213.
Features
Can accommodate regular cycles of high or low amplitude movement
Unaffected by moisture
Easy to install using finger pressure even in uneven gaps
A dry system
For vertical or horizontal wall applications
Installation
Ensure gaps to be filled are the correct specified size and consistent width. Excessive construction tolerance should be notified to the site manager or engineer.
Confirm period of fire resistance specified corresponds to product specification as delivered to site.
Check for obstructions to the gap such as ties between steel and masonry and mortar snots. Intuspan will have to be cut around unavoidable obstructions such as ties.
Carefully remove a length of Intuspan from its packaging and starting from one end compress between finger a thumb and insert into the gap to either side of the partition/floor, or in the middle, whichever is convenient. Use straight, close butt joints.
It is not normally necessary to use adhesive to retain Intuspan in a gap, nor is it necessary on butt joints. If excessive construction tolerance causes installation problems, report the matter to the site manager or engineer immediately.
If it is intended to install a mastic bead over Intuspan then Intuspan should be set back into the joint to an appropriate depth, normally 10 mm would be sufficient.
Finally, inspect the finished work to ensure no sections are loose.
Place off cuts and waste in strong plastic bags for disposal.
Fire Testing
Tested to BS EN 1366-4 and BS 476 Pt 22 to provide 2 hours fire stability and integrity
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contactedto obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditionsand should be applied only by an individual with the necessary expertise and experience.We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.
Nullifire FJ400 Intuspan is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
An extensive range of accessories and ancillary products for use with Nullifire (Firetherm) systems, helping the installation and application of firestopping products. Refer below to see the full range. More Information Delivery Info