We no longer stock this product; please contact our technical team on 0113 2455450 (option 2) or send a message to [email protected] where we will be happy to find an alternative product.
Nullifire (Firetherm) FV060 Ventilated Facade Cavity Closer, a fire barrier for use within rain screen cladding systems that maintains fire integrity for up to 60 minutes.
Not for use with combustible cladding types
Available in 1200mm lengths
For 50mm and 25mm cavities
Maintains compartmentalisation, preventing the spread of fire and smoke
Not recommended for us against combustible cladding; the integrity and insulation of Rainbar is limited by the capability of surrounding substrates.
Rainbars
Product
Size
Max. Free Air Space
Maximum Cavity
Rainbar
1200 x 60 x 8 mm
50 mm
58 mm
Rainbar
1200 x 60 x 4 mm
25 mm
29 mm
Accessories
Product
Size
Use
Rainbar Spike
Small (165mm long)
Fixing
Large (340mm long)
V-Lock (made to order dependent on cavity width)
Z Clips
300 x 30 x 0.8 mm
For fixing to non-fire-rated cladding
Nullifire FV060 Ventilated Facade Cavity Closer fire barrier provides fire protection for cavities in a rain-screen cladding system, maintaining compartment lines to the exterior of a building. The design leaves a gap for free airflow movement and the drainage of moisture, preventing mould growth and dampness within the cavity, with a polymeric encapsulation ensuring pooling water does not remain on the face of the Rainbar.
Made from a high pressure graphite-manipulated intumescent composite contained within a waterproof seal, the Rainbar cavity barrier expands across a cavity when attacked by fire, sealing up gaps and maintaining fire integrity for up to 60 minutes. By slowing down the spread of fire more time may be allowed for evacuation, potentially saving lives, and preventing further cosmetic or structural damage to buildings.
The simple fixing system allows for speedy installation on site. Rainbar is both lightweight and durable and requires no further maintenance and requires no further sealing.
Features
Ultra-slim design ensures easy installation in awkward situations
Fully tested at Exova BM TRADA up to 60 minutes integrity
Lightweight and durable
No maintenance, no further sealing required
Fixings
Fixing centres may not exceed 400 mm. Joint to joint fixing centres may not exceed 400 mm and may not be less than 100 mm from the joint.
All pieces exceeding 600 mm require a minimum of 3 fixings.
Minimum fixings cut pieces 300 mm - 600 mm = 2 (100 mm from joints). Smaller pieces always require two fixings at equal distance from the centre line.
Fixings should be located centrally through the depth of the product +/- 5mm to the centre line.
Fire Testing
Tested at Exova BM Trada to BS EN 1363-4
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contactedto obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditionsand should be applied only by an individual with the necessary expertise and experience.We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.
Nullifire FV060 Ventilated Facade Cavity Closer is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
An extensive range of accessories and ancillary products for use with Nullifire (Firetherm) systems, helping the installation and application of firestopping products. Refer below to see the full range. More Information Delivery Info