Tenmat FF109 Vent Duct Fire Sleeves Low Profile

    TEN5009

    CE Marked fire penetration seals designed to firestop PVC ventilation ducts/pipes when installed through fire rated constructions.

    • Fire rated product up to EI 120 minutes
    • Tested for masonry, concrete and plasterboard walls
    • Tested in external wall / SFS constructions
    • Can be installed within Ablative Coated Fire Batts
    • U/U - Uncapped/Uncapped tested as required for ventilated systems
    • Can be retro fitted
    • Low profile design
    • Available preformed and ready to install in both circular or rectangular shapes
    • Compressible material, offers accommodation for deflection
    • No metal sleeving or boxing out required
    • Note: some sizes are currently only available on a 20-30 working day delivery service - please see below for more information

    Item
    £20.27(ex. VAT)
    £24.32 (inc. VAT)
    Quantity
    Please choose your colour
    Available for Delivery (See Delivery Options Below)

    Description
    RefItemAvailability
    VDS100x180TENMAT FF109 Circular vent duct sleeve LP 100mmIn Stock
    VDS110x54x180TENMAT FF109 Rectangular vent duct sleeve LP 110x54x180mmIn Stock
    VDS125x280TENMAT FF109 Circular vent duct sleeve LP 125mmIn Stock
    VDS150x280TENMAT FF109 Circular vent duct sleeve LP 150mmIn Stock
    VDS204x60x180TENMAT FF109 Rectangular vent duct sleeve LP 204x60x180mmIn Stock
    VDS204x60x360TENMAT FF109 Rectangular vent duct sleeve LP 204x60x360mm25 working days
    VDS220x90x180TENMAT FF109 Rectangular vent duct sleeve LP 220x90x180mmIn Stock
    VDS220x90x360TENMAT FF109 Rectangular vent duct sleeve LP 220x90x360mm25 working days

    A length of Aluminium Foil Repair Tape is provided with each sleeve within the price quoted for use during fitting

    The FF109 Vent Duct Fire Sleeve Low Profiles (VDS LPs) are a family of CE Marked fire penetration seals designed to firestop PVC ventilation ducts/pipes when installed through fire rated constructions.

    The unique vacuum formed intumescent material design ensures that the expansion direction of the material crushes and seals the ducting in a fire situation without the need for any additional support or metal sleeving.

    The lack of metal sleeving, not only makes installation easy, it also limits the risk of heat transfer through the structure as well as allowing compression to ensure a tight seal against fire and smoke or tight fitting against the ceiling soffit where needed.

    The Fire Sleeves provide fire resistance ratings for Integrity (E) and Insulation (I) for up to EI120 minutes depending on the construction.

    Fire Tested for both internal and external wall constructions. The Fire Sleeves are CE Marked with a European Technical Approval (ETA) based on extensive fire testing to BS EN 1366-3.



    Quick Links - Click To Jump To Section:




    Ordering References


    RefDuct SizeNominal ThicknessNominal External Width/DiameterNominal External HeightLengthFire Rating
    VDS110x54x18010-15 mm25 mm134 mm83 mm180 mm*Up to EI120
    VDS204x60x18010-15 mm25 mm228 mm89 mm180 mmUp to EI120
    VDS204x60x36010-15 mm30 mm228 mm89 mm360 mmUp to EI120
    VDS220x90x18010-15 mm25 mm244 mm124 mm180 mmUp to EI120
    VDS220x90x36010-15 mm25 mm244 mm124 mm360 mmUp to EI120
    VDS100x18015 mm30 mm134 mm-180 mmUp to EI120
    VDS125x28015 mm30 mm160 mm-280 mmUp to EI120
    VDS150x28020 mm35 mm200 mm-280 mmUp to EI120



    Examples of Applications & Approvals


    See the data sheet (available to download from the data sheet tab above) for installation variations and diagrams for dry wall and rigid wall, fire batts and ducts from 30 minutes up to 120 minutes.



    General Fitting Instructions


      1. If using a hole cutter for circular holes, ensure that the correct fire sleeve wall thickness (15mm + 15mm) 30mm total is added to the diameter of the pipe, this equals the aperture size. Cut the hole through the substrate using the correct blade, in the required location.
      2. If cutting without a hole cutter, using a pencil, draw around the fire sleeve at the required position of the aperture, ensure a tightly marked line. Use this line to cut the aperture through the substrate, using the required equipment as appropriate.
    1. Unless the sleeve can be slid down the length of pipe/vent/duct to the aperture, carefully cut along the length of the fire sleeve, using a sharp knife or scissors, on a rectangular duct/vent cut centrally to one of the sides, place the sleeve around the pipe/duct/vent close to the aperture, and apply foil tape over the joint, where the sleeve was cut.
    2. Push gently on the sleeve to pass it through the wall, if the sleeve covering starts to tear or if excessive resistance is felt, pull the sleeve back and trim the aperture. The sleeve should be pushed into the required position, ensuring that the required length of sleeve protrudes on either side of the wall.
    3. If required for the purpose of smoke and draft stop, air or water tightness and airborne sound insulation, the gap between opening edge and fire sleeve may be sealed off by a suitable acrylic intumescent mastic construction sealant approved for penetration sealing applications.

     

    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



    Product Details
    5009-862399

    Data sheet

    Manufacturer
    Tenmat
    For Use By
    Professional Use
    Interior / Exterior Use
    Interior & Exterior
    Single, Two or Three Pack
    Single
    Suitable For Use On
    Concrete
    Suitable For Use On
    Masonry
    Suitable For Use On
    Plasterboard
    Product Usage Type
    Duct Sleeve
    Colour Family
    Red
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Tenmat FF109 Vent Duct Fire Sleeves Low Profile is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT