    Tenmat FF108 Cable Basket Fire Sleeves offer a quick and simple way to maintain the fire and acoustic ratings of cable basket penetrations. Supplied in a standard length to suit all common wall constructions, the ready to install design does not require any additional metal work, support, fire rated sealants or foams.

    • 2 hours Fire Rated
      • BS 476: Part 20
      • Acoustically tested in accordance with BS EN ISO 140-3:1995 and BS EN ISO 717-1:1997
    • Acoustically rated
    • Simple to install
    • No mastic, screws, or metal sleeving required
    • Can be fitted prior to running cables
    • Firestops both the cable basket and cables
    • Note: some sizes are currently only available on a 2-3 week delivery service - please see below for more information

    Quantity
    Product not available
    This Product has been Discontinued

    Description
    ItemDelivery Service
    FF108 Cable Basket Fire Sleeve 75x54x180mm2-3 weeks
    FF108 Cable Basket Fire Sleeve 100x54x180mm2-3 weeks
    FF108 Cable Basket Fire Sleeve 150x54x180mmAvailable Now
    FF108 Cable Basket Fire Sleeve 200x54x180mm2-3 weeks
    FF108 Cable Basket Fire Sleeve 250x54x180mmAvailable Now
    FF108 Cable Basket Fire Sleeve 300x54x180mmAvailable Now
    FF108 Cable Basket Fire Sleeve 400x54x180mm2-3 weeks
    FF108 Cable Basket Fire Sleeve 450x54x180mm2-3 weeks
    FF108 Infill Material 20x180x1000mmAvailable Now

    Tenmat FF108 Cable Basket Fire Sleeves offer a quick and simple way to maintain the fire and acoustic ratings of cable basket penetrations. The compressible and fully intumescent material provides an effective fire and acoustic seal around both the cables and the cable basket itself. The Sleeves have been fire tested to BS 476: Part 20 and acoustically tested in accordance with BS EN ISO 140-3:1995 and BS EN ISO 717-1:1997.

    The Cable Basket Fire Sleeves are supplied in a standard length to suit all common wall constructions. The ready to install design does not require any additional metal work, support, fire rated sealants or foams.

    The use of Cable Trays and Cable Baskets is on the increase as the amount of cabling within buildings continues to grow. Cables are routed through a wide variety of building types including hospitals, apartments and hotels.

    All buildings have walls and floors with fire and acoustic ratings. When cables are installed through such constructions their integrity and ability to perform to the required fire and acoustic standards are significantly reduced.



    Quick Links - Click To Jump To Section:




    Features & Benefits


    • 2 hours Fire Rated
      • BS 476: Part 20
      • Acoustically tested in accordance with BS EN ISO 140-3:1995 and BS EN ISO 717-1:1997
    • Acoustically rated
    • Simple to install
    • No mastic, screws, or metal sleeving required
    • Can be fitted prior to running cables
    • Firestops both the cable basket and cables



    Ordering References


    To Suit Cable Basket SizeNominal ThicknessNominal External Width/ DiameterExternal HeightLength
    75 x 54 mm25-30 mm145 mm114 mm180 mm
    100 x 54 mm25-30 mm170 mm114 mm180 mm
    150 x 54 mm25-30 mm220 mm114 mm180 mm
    200 x 54 mm25-30 mm272 mm114 mm180 mm
    250 x 54 mm25-30 mm324 mm114 mm180 mm
    300 x 54 mm25-30 mm374 mm114 mm180 mm
    400 x 54 mm25-30 mm478 mm114 mm180 mm
    450 x 54 mm25-30 mm528 mm114 mm180 mm



    General Fitting Instructions


    • Use the Fire Sleeve as a template when cutting the plasterboard to provide a snug fit around the Fire Sleeve
    • Slit the sleeve along its length to allow easy installation around cable tray or basket

     

    • Fit sleeve around tray or basket and re-seal with aluminium repair tape supplied

     

    • Once cables have been installed they should be tightly sealed with TENMAT Infill Material

     

    • If required, an intumescent sealant can be used to ensure a smoke and acoustic seal
    • Installation in solid walls is also approved



    Test Data


    Report TypeFire Test LabReport NumberTest StandardConstructionRating
    AssessmentChiltern FireA12121BS 476 & BS EN 1366-3Plasterboard, Blockwork60-120 min
    Fire TestExova WarringtonfireIF05040BS 476Concrete floor, Partition120 min
    Fire TestExova WarringtonfireIF05044BS 476Partition90-120 min
    Fire TestExova WarringtonfireIF08029BS 476Partition60 min



    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

    Product Details
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Tenmat FF108 Cable Basket Fire Sleeves is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT