Astroflame High Pressure Expanding Sealant

    AST5323

    An acrylic based graphite sealant used to reinstate the fire resistance performance of wall and floor constructions where they have been provided for the penetration of single or multiple services, to form penetration seals where gaps are present.

    • Expands upon contact with heat (also known as intumescent or reactive material)
    • Suitable for use in rigid wall and floors, flexible wall and batts in wall and floor
    • Linear Joints up to 20mm wide
      • Large service openings up to 300 x 100mm
      • Batt aperture up to 1100mm x 750mm
      • Metallic Pipes, Cables, Cable Bunches (inc Telecommunication), Cable Trays and Cable Ladders
      • Combustible Pipes up to 125mm dia - PVC, PE, PP, ABS and PEX.
    • Use with sealing elastromeric foam and glass wool insulation
    • Suitable for use in irregular applications
    • Causes no known effects to plastic pipes, plastic cables, sheathing or metallic components
    • Contributes to Green Building
    • Easy clean up with water and is odourless
    • Long life and paintable
    • Smoke, gas, water tight and air tight
    • High Expansion Ratio
    • Resists fungi and vermin

    Please Note: 600ml pack size is subject to a MOQ of 480 units

    Colour
    Size

    £67.68 (incl. VAT)

    £56.40 (ex. VAT)

    Quantity
    Please choose your colour
    Available for Delivery (See Delivery Options Below)

    Description

    Astroflame HPE Sealant is an acrylic based graphite sealant used to reinstate the fire resistance performance of wall and floor constructions where they have been provided for the penetration of single or multiple services, to form penetration seals where gaps are present.

    Astroflame HPE Sealant expands upon contact with heat, also known as intumescent or reactive material. The sealant is gunned or trowelled into the annular space in or between the separating element/elements to a specific depth utilising backing materials.



    Quick Links - Click To Jump To Section:




    Features & Benefits


    The intended use of Astro HPE Sealant is to reinstate the fire resistance performance of rigid and flexible wall and floor constructions where they are penetrated by various cables, plastic and insulated metallic pipes.

    The specific elements of construction that the system Astro HPE Sealant may be used to provide a penetration seal in, are as follows:

    • Suitable for use in rigid wall and floors, flexible wall and batts in wall and floor
    • Linear Joints up to 20mm wide
    • Large service openings up to 300 x 100mm
    • Batt aperture up to 1100mm x 750mm
    • Metallic Pipes, Cables, Cable Bunches (inc Telecommunication), Cable Trays and Cable Ladders
    • Combustible Pipes up to 125mm dia - PVC, PE, PP, ABS and PEX.
    • Use with sealing elastromeric foam and glass wool insulation
    • Suitable for use in irregular applications
    • Causes no known effects to plastic pipes, plastic cables, sheathing or metallic components
    • Contributes to Green Building
    • Easy clean up with water and is odourless
    • Long life and paintable
    • Smoke, gas, water tight and air tight
    • High Expansion Ratio
    • Resists fungi and vermin



    Technical Data


    Technical Data - Product Overview
    DescriptionResultTest Standards
    DensityCa. 1.23 - 1.33g/cm³ISO 2811-1:2011
    Shore Hardness A68ISO 7619-1:2010
    ColourGrey 
    Application Temperature5 °C to 35 °C 
    Expansion Onset TemperatureCa. 180 °C 
    ExpansionUp to 20 times 
    Skin Time15 minutes @ 25 °C/ 50%RH 
    Cure Time1.7mm per 24hrs 
    Shelf Life18 months in unopened 
    pH6 - 9 
    Fire ResistanceEI 120EN1366-3 and EN1366-4
    Insulation120EN 1366-3
    Air Permeability600Pa - 100Pa 11.1/16.7 m3/h/m2EN1026
    ClassificationEN 13501-2, ISO 11600 
    ManufactureISO 9001:2008 
    AcousticsRw (C;Ctr) : 52 (-1;-6) dBEN ISO 10140-2:2010
    Durability ServicesType Z1, intended for use in internal conditions

     

    VOC%w/w Non volatiles (105°C)%w/w water% Nonaqueous volatiles (105°C)
    Astro HPE Sealant64.6726.17 
     65.2926.858.5
    Mean6526.5



    Installation


     

    Backing Material

    The backing material that can be used for Astro HPE Sealant, Mineral wool (min. 80kg/m3) or PE backing rod where required. Backing material is not needed within all installations, though the Astro HPE Sealant should be installed correctly to achieve the performance needed.

     

    Installation

    Ensure that the aperture and services in question are tested with Astro HPE Sealant, and the site conditions are within the application specification. Efficient annular space needs to be present around the service to apply sufficient installation depth.

    All service's and apertures need to be clean and clear of all dust and loose particles. The aperture temperature needs to at 5℃ or above at time of installation.

    Upon installation make sure that you install the Astro HPE Sealant 20mm annular and 25mm deep around all services effectively, make sure that you fill all of the annulus and to compact the Astro HPE Sealant into the annular gap.

    Once compacted smooth off the Astro HPE Sealant to produce a nice professional looking finish.

    Please refer to the Technical Data Sheet (also available from the Data Sheets tab further above) for more data on the following installations:

     

    Floor Application

    • Rigid floor constructions with floor thickness of minimum 150mm
      • Insulated Metallic Pipes
      • Plastic Pipes
      • Plastic Pipes, Conduits and Cables
      • Metallic Pipes With Insulation
      • Cables and Cable Trays

     

    Substrates

    The floors shall be a minimum of 150mm thick. Masonry / Concrete floors shall have a minimum density for concrete or brick of 780kg/m³ and for aerated concrete blocks of 600kg/m³. All floors shall have at least the same fire rating as that required for the Sealing system.

    Service support Requirements

    Services should be rigidly supported via steel angles, hangars or channels, not further than 450mm from the surface of the sealing system on both faces unless specified otherwise in the performance data.

    Terminology

    Fire performance in accordance with EN1366-3, EN1366-4, Classification 13501-2:2007 + A1:2009, ETAG-026, Air Permeability EN1026, Sound EN10140. Fire resistance classes are: E = Integrity, the product can withstand the fire from the non-fire side, I =Insulation, the product can withstand the temperature traveling down the service, U/U = Uncapped inside and outside the furnace, U/C = Uncapped inside and Capped outside the furnace, C/U = Capped inside and Uncapped outside the furnace.

     

    Wall Application

    • Flexible and Rigid wall constructions with wall thickness of minimum 100mm
      • Plastic Pipes
      • Penetration seal with PS Coating and Astro HPE Sealant - Metallic Pipes
    • Flexible and Rigid wall constructions with wall thickness of minimum 120mm
      • Plastic Pipes and Cables
      • Insulated Metallic Pipes
    • Astro HPE Linear Joint Seals. Min 120mm thick Flexible or Rigid Wall
    • Rigid wall with a minimum thickness of 150mm

     

    Substrates

    The walls shall be a minimum of 100mm thick. Drywalls shall comprise a minimum of 2 layers of ‘Type F’ Gypsum board on both faces, with minimum 50mm studs. Masonry / Concrete walls shall have a minimum density for concrete or brick of 780kg/m³ and for aerated concrete blocks of 600kg/m³. All walls shall have at least the same fire resistance as that required for the sealing system.

    Service support Requirements

    Services should be rigidly supported via steel angles, hangars or channels, not further than 450mm from the surface of the sealing system on both faces unless specified otherwise in the performance data.

    Terminology

    Fire performance in accordance with EN1366-3, EN1366-4, Classification 13501-2:2007 + A1:2009, ETAG-026, Air Permeability EN1026, Sound EN10140. Fire resistance classes are: E = Integrity, the product can withstand the fire from the non-fire side, I =Insulation, the product can withstand the temperature traveling down the service, U/U = Uncapped inside and outside the furnace, U/C = Uncapped inside and Capped outside the furnace, C/U = Capped inside and Uncapped outside the furnace.

     

    Batt Application

    • Flexible and Rigid wall constructions with wall thickness of minimum 100mm
      • Astro Batt Penetration Seal and Astro HPE Sealant - Insulated Metallic Pipes
      • PS Coating Penetration Seal and Astro HPE Sealant - Insulated Metallic Pipes
    • Astro HPE Penetration Seals. Single Layer of 50mm Thick Astro Batt Installed Within Min. 150mm Thick Rigid Wall - Plastic Pipes
    • Cables and Cable Trays
    • Astro HPE Penetration Seals. Single layer of 50mm thick Astro Batt Installed Within Min. 150mm Thick Rigid Wall
    • Astro HPE Penetration Seals. Double Layer of 50mm Thick Astro Batt Installed Within Min. 150mm
      • Thick Rigid Floor
      • Cables and Cable Trays
    • Astro HPE Penetration Seals. Double layer of 50mm thick Astro Batt Installed Within Min. 150mm Thick Rigid Wall
      • Plastic Pipes
      • Cables and Cable Trays
    • Astro HPE Penetration Seals. Double layer of 50mm thick Astro Batt Installed Within Min. 150mm Thick Rigid Floor
    • Flexible and Rigid wall constructions with minimum wall thickness of 100mm, Penetration seal with Astro Batt and Astro HPE Sealant installed centrally within the wall

     

    Substrates

    The walls shall be a minimum of 100mm thick. Drywalls shall comprise a minimum of 2 layers of ‘Type F’ Gypsum board on both faces, with minimum 50mm studs. Masonry / Concrete walls shall have a minimum density for concrete or brick of 780kg/m³ and for aerated concrete blocks of 600kg/m³. All walls shall have at least the same fire resistance as that required for the sealing system.

    Service support Requirements

    Services should be rigidly supported via steel angles, hangars or channels, not further than 450mm from the surface of the sealing system on both faces unless specified otherwise in the performance data.

    Terminology

    Fire performance in accordance with EN1366-3, EN1366-4, Classification 13501-2:2007 + A1:2009, ETAG-026, Air Permeability EN1026, Sound EN10140. Fire resistance classes are: E = Integrity, the product can withstand the fire from the non-fire side, I =Insulation, the product can withstand the temperature traveling down the service, U/U = Uncapped inside and outside the furnace, U/C = Uncapped inside and Capped outside the furnace, C/U = Capped inside and Uncapped outside the furnace.

     

    Uponor Application - Uponor Valve System

    The drywall construction was of overall dimensions 3000mm wide by 3000mm high by 100mm thick. The framing comprised 50mm wide galvanised mild steel studs, at maximum 600mm centres, friction fitted into galvanised steel head and base channels.

    Each side of the stud frame was faced with two layers of 12.5mm thick ‘Gypsum’ Type F plasterboard. The framework was infilled with 50mm thick mineral wool insulation having a nominal density of 100kg/m3.

    The wall was provided with eight circular apertures, which was penetrated by a range of shower units.



    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

    Product Details
    5323-874213

    Data sheet

    Manufacturer
    Astroflame
    For Use By
    Professional Use
    For Use On
    Walls
    Floors
    Application Method
    Application Gun
    Trowel
    UN Number
    N/A
    Colour(s)
    Standard Colours
    Base Type
    Acrylic-Based
    Application Method
    Application Gun
    Application Method
    Trowel
    Manufacturer
    Astroflame
    Usages
    Fire Resistance
    Product Usage Type
    High Pressure Sealant
    Colour Family
    Grey
    Fire Rating
    120 Minutes
    Classification
    UL
    Classification
    CE
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Astroflame High Pressure Expanding Sealant is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT