PipeBloc PCP Collars are designed and tested to seal service penetration apertures containing plastic and metallic pipes with insulation or cables. They are developed to provide a high volume expansion and pressure seal during a fire. The ultra thin design of the collars means the collar shell can give a depth of 30mm and 40mm ensuring that they can be installed into the tightest of locations. Can be installed on flexible wall, rigid wall, rigid floor constructions and in Stopseal Batiseals.
Tested with a wide range of services, including plastic pipes, cables, insulated non-combustible pipes
Allows thermal and mechanical movement of pipe
Halogen free, contains no asbestos or ceramic and is environmentally friendly
Not effected by fungus, vermin, rodents or moisture
EI120 and EI240 tested results to EN1366-3
Conditioned to Type X: -20℃ to +70℃ with accordance with EOTR 024 and Etag 026
To reinstate fire resistance through walls and floors
To seal multi-service penetrations and cable bunches
Around combustible pipes from 32-250mm diameter
Angled combustible pipes through walls
Assumed working life 25 years
Easy fixing method using common fixings or ‘pigtail’ screws
PipeBloc PCP Collars are designed and tested to seal service penetration apertures containing plastic and metallic pipes with insulation or cables. They are developed to provide a high volume expansion and pressure seal during a fire. The PipeBloc PCP Collars offers EI120 and EI240 tested results to EN1366-3, the maximum diameter available being 250mm. The ultra thin design of the collars means the collar shell can give a depth of 30mm and 40mm ensuring that they can be installed into the tightest of locations. PipeBloc PCP Collars can be installed on flexible wall, rigid wall, rigid floor constructions and in Stopseal Batiseals.
Used around combustible pipes to form a penetration seal and to reinstate the fire resistance performance of wall and floor constructions, where they have been provided with apertures for the penetration of combustible pipe services.
PipeBloc PCP Collars includes an intumescent component incorporated into a mild steel case to close any gaps and to provide a closure of combustible pipes when heated to prevent the passage of fire.
Supplied in assembled form, without fixings. The collar is wrapped around the pipe at the soffit or both faces of walls, depending on application.
The specific elements of construction that the system PipeBloc PCP Collars may be used in as follows.
Suitable for use with flexible walls with > 100mm minimum thickness, rigid wall with > 100mm minimum thickness and rigid floors with 150mm minimum thickness also within the Stopseal Batt system
Features & Benefits
Allows thermal and mechanical movement of pipe
Halogen free, contains no asbestos or ceramic and is environmentally friendly
Ease of fixing to suit location - 5 fixing types available
Not effected by fungus, vermin, rodents or moisture
Conditioned to Type X: -20℃ to +70℃ with accordance with EOTR 024 and Etag 026
To reinstate fire resistance through walls and floors
To seal multi-service penetrations
To seal cable bunches
Around combustible pipes from 32-250mm diameter
Angled combustible pipes through walls
Assumed working life 25 years
For internal use
High performance intumescent
Easy fixing method using common fixings or ‘pigtail’ screws
Tested with a wide range of services, including plastic pipes, cables, insulated non-combustible pipes
Tested in accordance with EN1366-3:2009 – Fire Resistance – Penetration Seals
Classified in accordance with EN13501-2 – Fire Resistance
CE Marked – ETA 15-0489
Conditioned in accordance with EOTA TR024 – X Type
Certifire Accreditation – CF5367
ULEU Accreditation
UAE Certificate of Compliance
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contactedto obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditionsand should be applied only by an individual with the necessary expertise and experience.We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.
FSi PipeBloc PCP Intumescent Pipe Collars is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
An ablative-coated stonewool board used to reinstate the fire resistance performance of internal wall and floor constructions where apertures are penetrated by single or multiple services.Prevention of air leakage and provides smoke seal Maintains Acoustic performance Assumed working life 30 years Highly flexible, high performance...