The Ritherdon R5 FireSeal is a fire rated electric meter box incorporating a high temperature lock and fire-resistant backboard providing 60 minutes of fire protection.
The Ritherdon R5 FireSeal is a fire rated electric meter box incorporating a high temperature lock and fire-resistant backboard providing 60 minutes of fire protection. It is a more vandal-resistant and fire-resistant alternative to the plastic meter box, with the design matching most closely in appearance the standard Small GRP box.
Test reports can be found in the data sheets tab above
Currently there exists no standard test specifically for the evaluation of systems such as the FireSeal that reinstate the fire resistance of walls, however the BS 9991: 2015 Code of Practice for Fire Safety states that elements in a multi-storey block provide between 30 and 60 minutes of fire resistance. Section 24.3 states that access panels provide the same fire resistance as the element into which it is fitted, when tested in accordance with BS EN 1363, BS EN 1364 and BS EN 1366.
Fire resistance testing
Three tests were performed by Chiltern International Fire/BM TRADA/Exova Warringtonfire covering the whole fire rated product range. (Chilt/RF12153, BMT/FEP/F15263, BMT/FEP/F14180) Specimens were fixed to a supporting construction and an industrial furnace was used to simulate the effects and conditions of a fire. Two of each specimen were tested – one facing the furnace and the other facing away. Furnace was controlled to follow temperature-time relationship as specified in BSEN 1363: Part 1: 2012 Section 5.1.1. R5 meter-boxes maintained integrity for over 60 minutes, achieving E 60 rating.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.