Rockwool Fire Tube

    254806
    ROC8024

    Rockwool Fire Tube comprises of a range of simple to install, pre-formed cylindrical sections of non-combustible stone wool to suit standard steel pipe diameters.

    • Designed to provide fire protection of up to 4 hours
    • Fire Tube is suitable for use with structural steel, circular hollow sections (CHS), solid bars, sprinkler pipes and process pipework
    • Available in both plain and foil faced options
    • Tested to the latest Harmonised European standard, BS EN 13381-4:2013
    • Non-combustible (A1 in accordance with EN13501-1 tested and assessed by Warringtonfire Report No: WF 433895)
    • Excellent thermal and acoustic insulation - Water repellent - Simple to install

    Available to suit common steel structural column and pipe diameters (See Order References) and is supplied in lengths of 1000mm. 

    Item

    £61.25 (incl. VAT)

    £51.04 (ex. VAT)

    Quantity
    Please choose your colour
    Available for Delivery (See Delivery Options Below)

    Description

    Quick Links - Click To Jump To Section:




    Order References


    Item NumberDescriptionThickness (mm)Length (mm)Outer Diameter (mm)
    256917Foil Faced Fire Tube 301000114
    251605Plain Fire Tube501000169
    238417Plain Fire Tube601000169
    265364Plain Fire Tube251000324
    257386Plain Fire Tube401000253
    254807Foil Faced Fire Tube 40100042
    251604Plain Fire Tube501000114
    139639Foil Faced Fire Tube 40100089
    261715Foil Faced Fire Tube 40100076
    254806Foil Faced Fire Tube 40100027
    274732Fire Tube70100060



    Features & Benefits


    • Developed as a rigid pre-formed section to protect structural circular steel elements, as well other infrastructure such as process, sprinkler and service pipes
    • Manufactured from stone wool insulation, it offers cellulosic fire protection, with additional thermal and acoustic qualities
    • Easy to handle – the Fire Tube product is light and easy to cut into shape using a saw or a sharp knife
    • Please refer to the FIREPRO Book for full details of:
      • Technical Information
      • Performance
      • Specification Clauses
      • Installation
      • Health and Safety



    Fire Performance


    Fire Performance

    • Fire report CC 276856A details the expected fire resistance performance relating to critical steel temperatures of 50, 100, 150, 200, 250, 300, 350, 400 and 550°C for periods of up to 4 hours
    • The required wall thickness of Fire Tube to provide a particular fire resistance for a specified period depends on the diameter, wall thickness and critical (fail) temperature of the steel column or pipe. However, in the case of pipes, the critical temperature is likely to depend on its contents

    Structural Steel Fire Protection

    The section factors A/V (Hp/A) for standard structural steel sections can be found in the ASFP Yellow Book or can be calculated for each element by dividing the perimeter (circumference) exposed to fire (A) by the cross sectional area (V). For circular sections (including pipes), the following, simplified formulae can be used to calculate the A/V section factors:-

    • Solid sections: A/V = 4 / OD
    • Hollow sections: A/V = OD / (thk (OD - thk))
    • Where OD = outside diameter in m
    • Where thk = wall thickness in m

    Please see the FIREPRO Book in the 'Data Sheets' tab for detailed information including critical steel temperatures etc.

    Standards and Approvals

    • Fire Tube conforms to BS 3958: Part 4, ‘Bonded preformed mineral wool pipe sections’
    • Full-scale independent test data has been verified and assessed by BRE Global in Fire report number: CC 276856A
    • This product has been authorised for use in LUL surface and sub-surface premises when installed in accordance with this
      datasheet - please refer to the LUL Approved Product Register website www.LU-apr.co.uk for specific details



    Application Notes


    • Fire Tube is light and easy to cut to shape using a saw or a sharp knife
    • Abutted sectional joints/ tube ends of the Fire Tube (including the partially split ‘hinge’ and the tube ends) are to be applied with Rockwool Firepro Glue prior to application
    • All joints should be held firmly together with temporary bands of steel wire, jubilee clips or plastic cable ties at 200mm centres until adhesive within joints and between Tube ends has fully cured
    • If installed outdoors, Fire Tube must be protected from the weather
    • Prior to use, Fire Tube should be stored indoors or protected by a weather proof covering

    Please see the FIREPRO Book in the 'Data Sheets' tab for detailed information.



    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.



    Product Details
    8024-914784

    Data sheet

    Manufacturer
    Rockwool
    For Use By
    Professional Use
    Interior / Exterior Use
    Interior & Exterior
    For Use On
    Steel
    Suitable For Use On
    Steel
    Manufacturer
    Rockwool
    Product Usage Type
    Fire Wrap
    Fire Rating
    240 Minutes
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Rockwool Fire Tube is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT


    You might also like

    Rockwool Firepro Glue

    Rockwool FirePro Glue is a water based, fire resistant adhesive suitable for use with FirePro Beamclad and Rockwool Fire Duct Systems where glued joints or noggins are required.Can be used in conjunction with other Rockwool Stone Wool products where there is a requirement for a fire resistant adhesive Authorised for use in LUL surface and...

    Price £100.76 (ex. VAT)

    £120.91 (incl. VAT)

    £100.76 (ex. VAT)

    In Stock and Available for Delivery