Fire Protection and Decoration of Wood in Buildings
Thermoguard Timbercoat Insulating Basecoat
Thermoguard Timbercoat Insulating Basecoat is a durable, wear, weather and wash resistant fire protection paint for decorative interior and exterior timber surfaces. Thermoguard Timbercoat meets new Fire Regulations standard BS EN Class B s1 d0 and complies with British Standard Class 1 and Class O Surface Spread of Flame.
Intumescent and Water Vapour Action
When exposed to fire:-
Finish, Colours, Spread Rate and Pack Sizes
- Thermoguard Smoke & Flame Retardant (SFR) Dualcoat is available in Matt or Eggshell finish in White, BS 4800, BS 381C, RAL and NCS colours (not metallic or fluorescent shades)
- Timbercoat is available in White as standard but can also be tinted to BS 4800, BS 381C, RAL and NCS undercoat shades
Specification & Application
Prepare & apply according to manufacturer’s instructions
*Apply 2 coats of Thermoguard Smoke & Flame Retardant (SFR) Dualcoat for external or damp areas. 2 coats may also be required for strong/dark colours - Thermoguard Timbercoat will be provided in a suitable undercoat shade to aid topcoat opacity unless instructed otherwise.
Available as a system pack - please see Thermoguard Timbercoat BS Class 1/0 & EN Class B System.
For fire protection to doors, see Door Upgrade Products
Please note: Timber must be clean and thoroughly dry prior to application (maximum 18% moisture content). Any gaps should be sealed with Thermoguard Intumescent Mastic. Fire should be prevented from accessing unprotected wood surfaces and for external applications it is recommended wood has been sealed on the reverse face to stop water ingress.
NOT suitable for the topside of floor surfaces that will be trafficked/walked on.
Spray equipment suggestions for Thermoguard Timbercoat and Thermoguard Anti-Microbial SFR Dualcoat;
- Pressure Pot & Gun conventional unit with small compressor
- Ensure all traces of solvent flushed out
- Thin 5 > 10% with water to spray viscosity
- Adjust fluid flow & air flow as normal for acrylic emulsion paint
OR
- Airless Graco 1500, 3500 or equivalent
- 3/8” line, 30 mesh filter on machine, not filter in gun
- 521 or 523, broad areas 621 or 623 tip
Ensure coverage is applied as per can - i.e. 20m² can covers 20m², 80m² can covers 80m², etc.
Application to OSB/Sterling Board
This is a board made of chips of wood glued together to form a hard non-decorative board. If it needs fire coating, Thermoguard Fire Varnish or Timbercoat System can be applied to it to acheive BS Class 1/0 and EN Class B only. However we first recommend a test is carried out by applying a small amount of the proposed coating to the board to check for "cessing" / "cissing" (where coating gathers together in lumps and may leaving bare patches between). If this occurs the board should be degreased/cleaned and allowed to dry before testing again - if this still does not provide a satisfactory application please contact our Technical Team for further advice on 0113 2455450 (option 2) or send a message to [email protected].
UKAS Fire Test Standards
- BS EN Class B s1 d0
- BS Class 1 and Class 0
Project Fire Certification
We issue a Certificate of Supply on request for projects for insurance, Fire and Building Control Authority and Client Records.
Preparation
- Surfaces should be free of contamination, sound, clean and dry
- Thoroughly abrade knotting, gloss, hard or smooth paints. Check adhesion of any existing coatings
- Unknown coatings or old fire coatings – contact our Technical Department on 0113 2455450
Application Conditions
- Apply to dry wood in dry conditions
- Max. timber moisture content 18%
- Max. relative humidity 70%
- Min. temp 5°C and 2°C above dewpoint
- Protect from rain until 1st coat of Thermoguard Smoke & Flame Retardant (SFR) Dualcoat is dry
- Touch Dry: 4 hours / Overcoat: 6 hours
- Ensure fully hard dry before next coat, only apply to dry timber in good drying conditions
- For use on timber with a minimum thickness of 7mm.
NEW Fire Regulations and Tests Explained
- The new fire standard BS EN test lasts 20 minutes with airflow replaces the old BS 476 tests which lasted 10 minutes and restricted airflow
- The new standard for flamespread and heat release Class B replaces Class O
The new BS EN tests also monitor -
- Smoke & Gas “s” – s1 + s2 are none or very low & compliant levels, s3 moderate , s4 high smoke
- Flaming Droplets or Airborne particulates – dO is none, d1 some, d2 + d3 moderate > high levels
Durable & Eco Friendly
Thermoguard Timbercoat & Thermoguard Smoke & Flame Retardant (SFR) Dualcoat are water based, user and environment friendly.
Quality Assurance
Products are manufactured under ISO 9001.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.