RSL Resuprime MVT

PRDFB

RSL Resuprime MVT (formerly known as R.S. Dampshield FH) is a faster curing version of R.S. Dampshield, with overcoat times of 6 hours. A two-component epoxy resin primer, it enables even earlier access onto new or existing concrete substrates for screed and coating applications on carpets, tiles, vinyl and wood. 

Features and Benefits: 

  • Easy application
  • Use on substrates with hygrometer readings <97%
  • Solvent-free
  • Low odour
  • Great adhesion
Colour
Size
Finish
£19.80
VAT excluded

£23.76 Tax incl.
Quantity

Description

Resuprime MVT (formerely known as R.S. Dampshield FH) can be used on a variety of underlayments including concrete and polymer screeds, as long as they are able to withhold water effect. It can even be applied to substrates with hygrometer readings of up to 97%.

If your surface does not have a damp-proof membrane (DPM) or it has become ineffectual, be very careful to eradicate any hydrostatic pressure. This could cause the water flow to be directed elsewhere.

The screed or floor you are applying Dampshield to should be at least 50mm thick if unbonded and strong enough that an even coating can be achieved. 

RECOMMENDED USES

  • Concretes with no DPM
  • Where a DPM is ineffective
  • Polymer screeds
  • Cementitious underlayments

Preparation

New Concrete Floors: New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm sq. is required.

Existing Concrete Floors: Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and make sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out with Resuscreed PA.

Existing Floors (previously coated): All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. If the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.

Where Resuscreed PA is applied to masonry/concrete surfaces, care must be taken to ensure that surface preparation is thorough
but does not disfigure the surface.

Priming

Where the relative humidity of a substrate exceeds 85% ERH, Resuprime MVT should be specified and selected on the basis of hygrometer readings in accordance with BS 8203.

The number of coats to be applied is chosen in accordance with the following table.

ERH% - Required Coating Thickness 
75-85 - 1 coat of Resuprime MVT at 200 microns per coat 
85-92 - 2 coats of Resuprime MVT at 200 microns per coat 
92-97 - 3 coats of Resuprime MVT at 200 microns per coat

For further information please refer to recommended individual product data sheets.

Application

The ambient temperatures of the areas should not be allowed to fall below 15°C throughout the application and the curing period, as this could have an adverse effect on the appearance and colour of the system. Surface temperature must be above 10°C. Where possible it is recommended that the application area is heated to a minimum temperature of 15°C ideally to allow the ambient and substrate temperature to stabilise prior to installation.

Mixing: Pre-mix the base component to a uniform consistency then mix the entire contents of the base with the hardener. If a separate mixing bucket is being used for mixing ensuring all contents of both components are removed from the buckets supplied. Mix using a slow speed electric mixer for approximately two to three minutes until the two components have fully combined.

The mixed unit should be applied immediately by squeegee, roller or brush with a consistent procedure. Floor areas should be cross-rolled to ensure even application and to minimise roller marks.

Coverage rates may vary depending on profile and porosity of the substrate

It is your responsibility to read the Product Data Sheets (available below) before you place an order and prior to application of the product. The content of this website is our best recommendation and is not advice. Coverage rates quoted are approximate, you agree that coverage depends on the condition of the substrate, surface absorption, texture and application method. We ALWAYS recommend a trial area is coated to ensure the product meets your requirements before use.

Product Details
PRDFB

Data sheet

For Use On
Concrete, Polymer Screeds
Application Method
Squeegee, Roller, Brush
Sheen
Semi-Gloss
Colour
Standard / Ready Mixed
VOC Levels
Low (50-149 g/l)
Single, Two or Three Pack
Two-Pack
Pack Size
1KG, 5KG, 15KG
Application
Squeegee, Roller, Brush.
Coverage
5kg will cover 23m sq. @ 200 microns WFT
Touch Dry
6 Hours
UN Number (Activator)
UN3066
UN Number (Base)
UN3082

Be the first to ask a question about this product!


Question about the product

* Required fields
(read)
Send
You might also like

RSL Resuscreed PA

RSL Resuscreed PA (formerly known as Resupatch) is a three-pack epoxy resin mortar designed for rapid concrete repair in heavy duty environments. Features and Benefits:  Excellent mechanical properties Can be feather edged Abrasion and impact resistant Dust-free Concrete like in appearance Easy to apply Minimum surface preparation

Price £38.44
In stock