RSL Resuflor HB Clear

    4263
    RSL4263

    Resuflor HB Clear (formerly known as Resutop Clear) is a two-pack, high solids, high-build epoxy coating for application as a chemical resistant heavy duty floor coating, used as a clear sealer for decorative flooring systems such as RSL Resuflor Q Screed, producing a seamless, hard wearing, hygienic floor finish.

    • Low odour
    • Good colour stability
    • Excellent slip resistance with the use of selected aggregates
    • Excellent high gloss finish
    • Ready for light traffic in 12-16 hours
    • Recommended uses include in food processing and beverage areas, chemical plant rooms, engineering workshops, automotive & aviation areas and factory units
    • See below for technical information and data

    Colour
    Size
    £107.55(ex. VAT)
    £129.06 (inc. VAT)
    Quantity
    Please choose your colour
    Available for Delivery (See Delivery Options Below)

    Description

    Resuflor HB Clear (formerly known as Resutop Clear) is a two-pack, high solids, high-build epoxy coating for application as a chemical resistant heavy duty floor coating. The coating will provide a smooth gloss finish and is used as a clear sealer for decorative flooring systems such as Decora MS. Applied by squeegee, roller and paint brush the product is low odour producing a seamless, hard wearing, hygienic floor finish.



    Features & Benefits


    • Two-pack, high solids, high-build epoxy coating
    • Chemical-resistant heavy duty floor coating
    • Used as a clear sealer for decorative flooring systems such as Decora MS
    • High-build finish
    • High solids
    • Hygienic and easily cleaned
    • Low odour
    • Good colour stability
    • Excellent slip resistance with the use of selected aggregates
    • Excellent high gloss finish
    • Ready for light traffic in 12-16 hours
    • Recommended uses include:
      • Food processing and beverage areas
      • Chemical plant rooms
      • Engineering workshops
      • Automotive & aviation areas
      • Factory units
      • Decorative finishes
      • Used as a seal coat for various Sherwin-Williams flooring systems
    • See below for product data and application information



    Products required for this system


    • Primer : Resuseal WB, Resuprime ST or Use Resuprime MVT
    • System : As per specification
    • Surface Seal : Resutop Clear

     

    Information & Data
    Product Information
    FinishSmooth Gloss
    System Thickness (Recommended)200-250 microns WFT 172-215 microns DFT
    *The suggested thickness range is calculated based on average volume solid as a general recommendation for the specified condition and for each application may vary.
    Solids Content by Weight~100%
    Pack Make Up1 x Base 1 x Hardener
    Shelf Life36 months (Base & Hardener)
    StorageKeep out of direct sunlight. Store in a dry place, between 15°C and 30°C.
    Application Information (at 20°C)
    Coverage Rate (Theoretical)5 kg will cover 22.8m² @ 200 microns wet film thickness
    * Coverage rate is calculated based on a sealed and smooth surface and may vary based on the substrate roughness and other conditions.
    Pot LifeApprox. 25-30 Minutes from mixing, based on 5kg pack size.
    *The pot life may be shorter for larger pack sizes.
    Note: All mixed material must be used within the pot life time limit. if the material is left in the container after mixing and not used, it may release hazardous fumes due to exothermic reaction.
    Recoating Intervals6 hours or once surface has lost tackiness
    Light Traffic12-16 hours
    Full Traffic24-36 hours
    Full Chemical Cure7 days
    Technical Information
    The following figures are obtained from laboratory tests and RSL's experience with this product.
    Slip Resistance (Method BS7976 pt1-3 2002)Dry > 60
    Wet (Please consult Sherwin-Williams/Rawlins Paints Technical)
    The slip resistance of a floor surface can vary as a result of the installation process, conditions at the time of application and subsequent traffic. Inappropriate cleaning or maintenance can adversely affect the performance. For further advice on potential wet areas please consult Sherwin-Williams.
    Abrasion Resistance (Method BS8204 /ASTM D4060)N/A
    Temperature ResistanceTolerant of temperatures up to 45°c
    Chemical ResistanceGood Chemical Resistance - Consult Sherwin-Williams/Rawlins Technical on specific materials
    VOC147 g/l Calculated per full mixed unit



    Preparation


    New Concrete Floors:

    New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm² is required.

    Existing Concrete Floors:

    Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and make sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Resuflor Patch or Resuflor Screed.

    Existing Floors ( previously coated )

    All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. if the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.

    Where Resutop Clear is applied to masonry/concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.



    Priming


    Open and porous substrates may require priming with Resuseal WB Clear, also Resuprime ST may be used as primer on the dry substrates only with less than 75% ERH reading.

    Where the Relative Humidity of a substrate exceeds 75% ERH Resuprime MVT should be specified and selected on the basis of hygrometer readings in accordance with BS 8203. The number of coats to be applied is chosen in accordance with the following table.

    ERH %Required Coating Thickness
    75-851 coat of Resuprime MVT at 200 microns per coat
    85-922 coats of Resuprime MVT at 200 microns per coat
    92-973 coats of Resuprime MVT at 200 microns per coat

    For Further information please refer to recommended individual product data sheets.



    Application


    The ambient temperatures of the areas should not be allowed to fall below 15°C throughout the application and the curing period, as this could have an adverse effect on the appearance and colour of the system. Surface temperature must be above 10°C. Where possible it is recommended that the application area is heated to a minimum temperature of 15°C ideally to allow the ambient and substrate temperature to stabilise prior to installation.

    Mixing:

    Pre-mix the base component to a uniform consistency then mix the entire contents of the base with the hardener. If a separate mixing bucket is being used mix thoroughly ensuring all contents of both components are removed from the buckets supplied. Mix using a slow speed electric mixer for approximately two to three minutes until the two components have fully combined.

    The mixed unit should be applied immediately by squeegee, roller or brush with a consistent procedure. Floor areas should be cross-rolled to ensure even application and to minimise roller marks. Coverage rates may vary depending on profile and porosity of the substrate.

    NOTE: Applied coating should be protected from moisture during application and during the curing period. Exposure to moisture during this time can cause surface and colour variations.

     

    Product Details
    4263-556045

    Data sheet

    For Use By
    Industrial Use
    Interior / Exterior Use
    Interior Use
    Application Method
    Brush
    Roller
    Squeegee
    Sheen
    Gloss
    Colour
    Clear
    VOC Levels
    Low (50-149 g/l)
    Single, Two or Three Pack
    Two-Pack
    Pack Size
    5KG
    Solvent
    Epoxy
    Key Features
    Chemical resistant, heavy duty
    Dry to Recoat (at 20°C)
    6 hours or once surface has lost tackiness
    Fully Cured (at 20°C)
    7 days
    Pot Life (at 20°C)
    Approx. 25-30 Minutes from mixing, based on 5kg pack size.
    Coverage
    5 kg will cover 22.8m² @ 200 microns wet film thickness
    Recommended Thinner/Cleaner
    R.S. Industrial Floor Cleaner, R.S. Tyre Mark Remover, Degreaser W500 & R.S. Oil Remover.
    Unit Contents
    Base & hardener
    Compatible Primers
    Resuseal WB, Resuprime ST or Use Resuprime MVT
    Compatible Topcoats
    -
    Max. Application Temperature
    -
    Min. Application Temperature
    15°C
    Density
    -
    Solids by Volume
    -
    Heat Resistance (up-to)
    -
    VOC
    147 g/l Calculated per full mixed unit
    Shelf Life (from date of manufacture)
    36 months (Base & Hardener)
    UN Number (Activator)
    UN3066
    UN Number (Base)
    UN3082
    Dry for Light Traffic (at 20°C)
    12-16 hours
    Base Type
    Solvent-Free
    Suitable For Use On
    Floors
    Application Method
    Roller
    Application Method
    Brush
    Application Method
    Squeegee
    Components
    2K
    Product Usage Type
    Sealer
    Product Range
    Resuflor
    Colour Family
    Clear
    Product Type
    Epoxy
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    RSL Resuflor HB Clear is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT