RSL Resuflor SL X - Standard Readily Available Colours

    4264
    RSL4264

    Resuflor SL X (formerly known as Resuflor VF), a self-smoothing epoxy resin seamless floor finish with non-dusting aggregates, designed to provide a flat hard wearing gloss finish ideal for industrial use, following the profile of the existing floor with aesthetically pleasing results and good chemical resistance and durability.

    • Three part (Base, Hardener & Aggregate)
    • Seamless and Hygienic
    • Silica free
    • Ease of application
    • Dry for light traffic in 24 hours
    • Excellent abrasion and impact resistance, with good chemical resistance
    • Smooth finish for precise operation equipment
    • Recommended uses include in pharmaceutical production, printing and packaging areas, television studios, automotive production, domestic studios, industrial workshops, medical and healthcare
    • More colours - with minimum order quantities and longer lead times - are available on RSL Resuflor SL X - Special Colours

    Colour
    Pick a Colour
    • Current colour: RAL 9003 Signal White
    Close colour picker
    • RAL 1032 Broom Yellow
    • RAL 3011 Brown Red
    • RAL 3020 Traffic Red
    • RAL 5017 Traffic Blue
    • RAL 6002 Leaf Green
    • RAL 7035 Light Grey
    • RAL 7038 Agate Grey
    • RAL 7040 Window Grey
    • RAL 7042 Traffic Grey A
    • RAL 7043 Traffic Grey B
    • RAL 9003 Signal White
    • RAL 9011 Graphite Black
    Size
    Finish
    £178.52(ex. VAT)
    £214.22 (inc. VAT)
    Quantity
    Please choose your colour
    Available for Delivery (See Delivery Options Below)

    Description

    Resuflor SL X (formerly known as Resuflor VF) is a self-smoothing epoxy resin seamless floor finish with low VOC content, with non dusting aggregates designed to provide a flat hard wearing gloss finish 2-3 mm in thickness following the profile of the existing floor. The system gives aesthetically pleasing results with good chemical resistance and durability, ideal for industrial use.



    Features & Benefits


    • Epoxy resin floor finish
    • Seamless
    • Silica free
    • Low VOC
    • Provides a hard wearing durable floor for industrial use
    • Ease of application
    • Hygienic
    • Excellent abrasion and impact resistance
    • Good chemical resistance
    • Smooth finish for precise operation equipment
    • Recommended uses include:
      • Pharmaceutical production
      • Printing and packaging areas
      • Television studios
      • Automotive production
      • Domestic studios
      • Industrial workshops
      • Medical and healthcare
    • See below for product data and application information



    Products required for this system


    • Primer : Resuprime NT or R.S. Dampshield on damp surfaces, where required.
    • System : Resuflor SL X
    • Optional Finish Coat: Resupen WB Clear Matt for a matt finish

     

    Information & Data
    Product Information
    FinishSmooth Gloss
    Recommended thickness range2-3mm
    Solids Content by Weight100%
    Pack Make Up1 x Base 1 x Hardener 1 x Filler SL1 Aggregate
    Shelf Life12 months (Base, Hardener & Aggregate)
    StorageKeep out of direct sunlight. Store in a dry place, between 15°C and 30°C.
    Application Information (at 20°C)
    Coverage Rate (Theoretical)29.5kg will cover 7.8m² at 2mm thickness or 5.2m² at 3mm thickness
    * Coverage rate is calculated based on a sealed and smooth surface and may vary based on the substrate roughness and other conditions.
    Pot Life25-30 Minutes
    Recoating Intervals12-16 hours
    Light Traffic24 hours
    Full Traffic72 hours
    Full Chemical Cure7 days
    Technical Information
    The following figures are obtained from laboratory tests and RSL's experience with this product.
    Slip Resistance (Method BS7976-1 + A1 2013, Method BS7976-2 + A1 2013, Method BS7976-3 + A1 2013)Dry > 60
    Wet (Please consult Sherwin-Williams/Rawlins Paints Technical)
    The slip resistance of a floor surface can vary as a result of the installation process, conditions at the time of application and subsequent traffic. Inappropriate cleaning or maintenance can adversely affect the performance. For further advice on potential wet areas please consult Sherwin-Williams.
    Abrasion Resistance (BS EN 13892-4:2002)AR 0.5 (< 50 microns wear)
    Shore D Hardness ( BS EN ISO 868:2003)85
    Tensile Strength ( BS EN ISO 527-2:2012)20 N/mm²
    Flexural Strength (BS EN ISO 178 +A1:2013)45 N/mm²
    Bond Strength ( BS EN 13892-8:2002)>3 N (Substrate failure)
    Temperature ResistanceTolerant of temperatures up to 60°c
    Chemical ResistanceGood Chemical Resistance - Consult Sherwin-Williams/Rawlins Technical on specific materials
    VOC81 g/l Calculated per full mixed unit
    Life Expectancy3-5 years depending on applied thickness and subjected to traffic according to FeRFA classification. Sherwin-Williams terms and conditions will apply.



    Preparation


    New Concrete Floors:

    New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm² is required.

    Existing Concrete Floors:

    Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and make sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Resupatch.

    Existing Floors ( previously coated )

    All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. if the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.



    Priming


    Open and porous substrates will require priming with Resuprime NT on dry substrates only with less than 75% ERH reading.

    Where the Relative Humidity of a substrate exceeds 75% ERH Resuprime MVT should be specified and selected on the basis of hygrometer readings in accordance with BS 8203:2017. The number of coats to be applied is chosen in accordance with the following table.

    ERH %Required Coating Thickness
    75-851 coat of Resuprime MVT at 200 microns per coat
    85-922 coats of Resuprime MVT at 200 microns per coat
    92-973 coats of Resuprime MVT at 200 microns per coat

    For Further information please refer to recommended individual product data sheets.



    Application


    The ambient temperatures of the areas should not be allowed to fall below 15°C throughout the application and the curing period, as this could have an adverse effect on the appearance and colour of the system. Surface temperature must be above 10°C. Where possible it is recommended that the application area is heated to a minimum temperature of 15°C ideally to allow the ambient and substrate temperature to stabilise prior to installation.

    Mixing:

    Pre-mix the coloured component (base) to a uniform colour, then mix the entire contents of base with the hardener. If a separate mixing bucket is being used ensure all contents of both components are removed from the buckets supplied. Mix using a slow speed electric mixer for approximately one to two minutes until the two components have fully combined then add the aggregate slowly. Mix for a further 1-2 minutes until the aggregate has fully combined and there are no lumps. The mixed unit should be applied immediately.

    Resuflor SL X should be worked with a trowel or float to achieve an even smooth finish. This is best achieved by the application of smooth even pressure with the compound poured over the correct coverage rate after fixing the stop ends to control the flow of the material. Then roll the area with a spiked roller to achieve an even smooth surface and remove entrapped air. Do not re-roll the area later than 10-15 mins.

    The surface should be protected from temperatures of less than 10°C and moisture in the early stages of cure. This could adversely affect the flow, levelling and surface finish of Resuflor SL X.



    Maintenance and Cleaning


    Resuflor SL X should be cleaned with a regular industrial cleaning regime, after specified full chemical cure time limit, with a floor scrubber utilising R.S. Industrial Floor Cleaner or similar with dirty water being removed. Isolated localised cleaning can be carried out using R.S. Tyre Mark Remover, R.S. Fats, Oils & Grease Remover & R.S. Oil Remover.

    All surfaces should be thoroughly rinsed with clean water after the use of chemical cleaners.

    Please refer to the RSL Guide to Cleaning of Resin Floors

     

    Product Details
    4264-1007456

    Data sheet

    For Use By
    Industrial Use
    Interior / Exterior Use
    Interior Use
    Water / Solvent Based
    Solvent
    For Use On
    Concrete Floors
    Application Method
    Brush
    Roller
    Squeegee
    VOC Levels
    Low (50-149 g/l)
    Single, Two or Three Pack
    Three-Pack
    Pack Size
    29.5KG
    Solvent
    Epoxy
    Mixing Ratio
    -
    Key Features
    Chemical resistant, heavy duty, ideal for industrial use
    Dry to Recoat (at 20°C)
    12-16 hours
    Fully Cured (at 20°C)
    7 days
    Pot Life (at 20°C)
    25-30 Minutes
    Coverage
    29.5kg will cover 7.8m² at 2mm thickness or 5.2m² at 3mm thickness
    Recommended Thinner/Cleaner
    R.S. Industrial Floor Cleaner
    Unit Contents
    1 x Base 1 x Hardener 1 x Filler SL1 Aggregate
    Compatible Primers
    Resuprime NT, Resuprime MVT
    Compatible Topcoats
    Resupen WB Clear Matt
    Max. Application Temperature
    -
    Min. Application Temperature
    15°C
    Density
    -
    Solids by Volume
    -
    Heat Resistance (up-to)
    -
    VOC
    81 g/l Calculated per full mixed unit
    Shelf Life (from date of manufacture)
    12 months (Base, Hardener & Aggregate)
    UN Number
    UN3082, UN3066
    UN Number (Activator)
    UN3066
    UN Number (Base)
    UN3082
    Dry for Light Traffic (at 20°C)
    24 hours
    Dry for Full Traffic (at 20°C)
    72 hours
    Suitable For Use On
    Concrete Floors
    Finish
    Smooth Gloss
    Application Method
    Brush
    Application Method
    Squeegee
    Application Method
    Roller
    Components
    3K
    Product Usage Type
    Self Smoothing Screed
    Product Range
    Resuflor
    Colour Family
    Grey
    Average Application Thickness
    2-3mm
    Product Type
    Epoxy
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    RSL Resuflor SL X - Standard Readily Available Colours is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT