Rust-Oleum 5300 Epoxyshield Maxx

5342.5

Rust-Oleum 5300 Epoxyshield Maxx is a user friendly and easy to apply water-based 2 component epoxy concrete floor coating with an ultimate adhesion and durability: 

  • Maximum durability in just 1 coat
  • For medium to heavy traffic
  • Easy to apply, no primer required
  • Long-lasting gloss finish
  • Highly resistant against solvents and chemicals
  • Non-skid or decorative finish optional

Please contact Rawlins Paints` Technical Support Team on 0113 2455450 for more information.

Colour
  • Current colour: Clear Ivory - RAL 1015
Choose a colour
Close colour picker
  • Clear Ivory - RAL 1015
  • English Red
  • Light Grey - RAL 7035
  • Steel Grey - RAL 7001
Size
Finish
£75.42
VAT excluded

£90.50 Tax incl.
Quantity

Description

Rust-Oleum 5300 Epoxyshield Maxx

A user friendly and easy to apply water-based 2 component epoxy floor coating with an ultimate adhesion and durability.

  • Maximum durability in just 1 coat
  • For medium to heavy traffic
  • Easy to apply, no primer required
  • Long-lasting gloss finish
  • Best possible car tyre resistance
  • Highly resistant against solvents and chemicals
  • Non-skid or decorative finish optional



The product has an excellent wear, impact and abrasion resistance like foot and vehicle traffic. Resists chemicals and standing water. The product can be applied on concrete floors, which are completely clean and dry. It is not recommended to apply on smooth/dense concrete or concrete containing a curing compound, which will prevent a good adhesion. Can also be applied on old good adhering coatings.



Recommended Use

Epoxyshield 5300 MAXX can be applied on concrete floors, which are completely clean and dry. It is not recommended to apply on smooth/dense concrete or concrete containing a curing compound, which will prevent a good adhesion. Epoxyshield 5300 MAXX can also be applied on old good adhering coatings. Epoxyshield 5300 MAXX Additives:

  • Epoxyshield Antislip Additive (200.0.7) gives an excellent anti slip finish when mixed with Epoxyshield 5300 MAXX
  • Epoxyshield Decorative Chips (505.0.43) are specially designed for use in combination with Epoxyshield 5300 MAXX. The chips adhere permanently on the floor when they are sprinkled in the wet coating. They give a decorative finish and will also mask dirt and rugosity.



Technical Data
Density: 1,27
Gloss Level: Satin
Solids content in volume: 63.6%
Mixing Ratio: Base : Activator = 3 : 1 (volume)



Drying Times At 20°C/RH 50%
Dry To Handle: 16 hours (suitable for light foot traffic)
Dry To Recoat: 24 hours (suitable for normal foot traffic and heavy items)
Fully Cured: 7 days (suitable for vehicle traffic)
Pot Life: 2 hours (15°C), 1½ hours (21°C), 1 hours (26°C)
Induction Time: Brushing: 30 minutes (15°C), 10 minutes (20°C), Direct (25°C). Rolling: 45 minutes (15°C), 15 minutes (20°C), 5 - 15 minutes (25°C)



Directions for Use

Pour the contents of A into B and stir thoroughly for at least 3 minutes. Allow mixed product to stand (see table) before rolling the coating on to the surface. Do not leave container in direct sunlight. Mix again before applying. The product must be used within 1 to 2 hours of initial mixing (pot life, see table). This time decreases at higher temperatures. Do not mix Paint Chips with Epoxyshield 5300 MAXX.



Application Conditions

  • Apply when air (ambient) temperature is 15-35ºC and relative humidity is below 80%.
  • Concrete floors take a long time to warm up; make sure the previous day has also been at least 15ºC prior to painting. Minimum floor temperature for painting is 13ºC. Painting in mid afternoon ensures the best cure.



Application and Thinning: Roller

After the full 60 minutes use a paint roller (20 cm) to apply an even coat of Epoxyshield 5300 MAXX onto the surface. Apply in sections of 1,5 x 1,5 m so that Epoxyshield
Decorative Chips can easily be scattered on the freshly coated surface. Maintain a wet edge to prevent lap marks and gloss differences. Sprinkle the decorative paint chips onto the wet film (note: this step may be skipped if chips are not desired. This will not affect the performance of the coating). Immediately continue to coat the next section (note: fresh paint can be applied over the loose chips that lay outside the previously painted area). Only one coat is necessary.



Cleaning of Equipment / Spills

Wash all tools and equipment immediately with warm water and mild detergent. Allow any unused product to harden in the container and discard according to local regulations.



Remarks

Since the application time is only 1 - 2 hours (depending on temperature) it is advisable to apply the product with 2 persons. Have 1 person begin trimming edges and have another person begin rolling out the floor as specified.

  1. Sealed concrete: dripping a small amount of water onto the surface. If the water beads, a sealer is present and paint may not adhere properly.
  2. Moisture in the concrete: apply a sheet of plastic (e.g. garbage bag) to the floor. Tape down the edges and allow to set for 24 hours. If water droplets appear on the inside of the plastic or if concrete appears wet (darker in colour), moisture is trapped in the concrete.
  3. Loose concrete or concrete dust: if the concrete is loose, chipping or has concrete dust present, the coating will not perform properly unless all loose material and dust is removed and damaged areas are repaired.
  4. Floors treated with a levelling mortar or on anhydride floors.

It is your responsibility to read the Product Data Sheets (available below) before you place an order and prior to application of the product. The content of this website is our best recommendation and is not advice. Coverage rates quoted are approximate, you agree that coverage depends on the condition of the substrate, surface absorption, texture and application method. We ALWAYS recommend a trial area is coated to ensure the product meets your requirements before use.

Product Details
5342.5

Data sheet

Manufacturer
Rust-Oleum
Interior / Exterior Use
Interior
Water / Solvent Based
Water
For Use On
Concrete
Application Method
Roller
Sheen
Gloss
Colour
Standard / Ready Mixed
VOC Levels
Low (50-149 g/l)
Single, Two or Three Pack
Two-Pack
Pack Size
5L
Mixing Ratio
Base : Activator 3 : 1 (volume)
Dry to Recoat (at 20°C)
24 hours (suitable for normal foot traffic and heavy items)
Fully Cured (at 20°C)
24 hours (suitable for normal foot traffic and heavy items)
Pot Life (at 20°C)
1½ hours
Coverage
7m² per litre
Max. Application Temperature
35°C
Min. Application Temperature
15°C
Density
1,27
Solids by Volume
63.6%
VOC
53 g/l
Shelf Life (from date of manufacture)
5 years from date of production in unopened cans, if stored in dry, well ventilated areas, not in direct sunlight at temperatures between 5° and 35° C.
Touch Dry
16 Hours
UN Number (Activator)
UN3082
UN Number (Base)
UN3066
Attachments
Download


Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


questions Nicholas Taylor on 2019-02-11 17:11:41
Question: 

I have a barn covering 90sqm, the concrete floor was laid last summer. Part of the concrete in the entrance lays outside (10sq m) the rest internal. Which epoxy (or other) floor covering would you advise. It will be subject to vehicle use. Regards Nicholas Taylor

Answer: 

Most epoxies are not UV stable so we would instead recommend Blackfriar Professional High Traffic Floor Paint which will not chalk or fade on the external areas.

questions Mick on 2018-09-20 18:14:35
Question: 

Can Rust-Oleum Maxx be used on a concrete garden patio area?

Answer: 

No, for this kind of area we would instead recommend Rust-Oleum Tarmacoat.

questions Cathy Lister on 2017-10-31 09:41:35
Question: what is the cure time of the pot life @ 10° C?
Answer: 

Rust-Oleum 5300 Epoxyshield Maxx should be applied when air (ambient) temperature is 15-35ºC and relative humidity is below 80%.

Concrete floors take a long time to warm up; make sure the previous day has also been at least 15ºC prior to painting. Minimum floor temperature for painting is 13ºC. Painting in midafternoon
ensures the best cure.

At 15ºC you will have around 2 hours of pot life - full details of induction and application times are listed on page 1 of the TDS (Technical Data Sheet) which can be downloaded from the 'DATASHEETS' tab on the product page.


Question about the product

* Required fields
(read)
Send
You might also like

Rust-Oleum Epoxyshield Decorative Flakes

Rust-Oleum Epoxyshield Decorative Flakes (Chips) are intended for use with their Epoxyshield Garage Floor Coating or Epoxyshield Maxx however it can also be used with other Rust-Oleum Mathys Floor Coating Systems. • One sachet will cover approximately 25m²• Broadcast/Scatter the flakes by hand or sieve• Can be used in conjunction with...

Price £6.86
In stock

Rust-Oleum Epoxyshield Anti-Slip Additive

Rust-Oleum Epoxyshield Anti-Slip Additive can be added to any of the Epoxyshield Floor Coatings range - Epoxyshield Ultra, Epoxyshield Sealer, Epoxyshield Maxx and Epoxyshield Garage Floor Coating to produce a non-skid surface. Non-skid floor additive based on thermally split flint stones Formulated for use with Epoxyshield floor coatings...

Price £5.33
In stock