Axalta Floorcote AQ200 is a two pack, water-based epoxy floor coating for use on a range of substrates.
It is suitable for application where low odour and minimum solvent content are important, such as schools, hospitals and public buildings, and it offers excellent abrasion resistance, adhesion and chemical resistance.
Axalta Floorcote AQ200 is suitable for use on concrete, wood, stone, tiles and previously painted sound surfaces.
Approvals/Certification - Conforms to Category (j) of Directive 2004/42/EC, which carries a VOC limit of 140g/l - please consult Axalta Coating Systems or Rawlins Paints Technical Department on 0113 2455450 (option 2) or send a message to [email protected] for more information.
Two pack, water-based epoxy floor coating for use on a range of substrates
Suitable for application where low odour and minimum solvent content are important, such as schools, hospitals and public buildings
Excellent abrasion resistance, adhesion and chemical resistance
Can be used on concrete, wood, stone, tiles and previously painted sound surfaces
Product Specification
Technical Data
Axalta Floorcote AQ200
Volume Solids
55 ± 2% depending on colour
VOC Content
3 g/litre (varies with colour)
SG
1.36 kg/lt mixed (varies with colour)
Storage Conditions
Store in dry, cool conditions and protect from frost
Shelf Life
Minimum 12 months if stored as above in unopened containers
Flash Point
Above 60°C
Pot Life
2 hours at 23°C
Film Thickness Range And Coverage
Film Thickness Range & Coverage
Dry Film Thickness
Wet Film Thickness
Theoretical Coverage
Minimum
70 µm
127 µm
7.8 m 2/litre
Maximum
90 µm
163 µm
6.1 m 2/litre
Practical coverage depends on the application method, painting conditions and the shape and roughness of the surface to be coated
Drying Times
Drying Times
Applied to 80 microns DFT
10℃
23℃
35℃
Dust Free
10 hr
7 hr
5 hr
Hard Dry
24 hr
16 hr
12 hr
Full Cure
7 Days
7 Days
5 Days
Overcoating
Minimum
24 hr
24 hr
24 hr
Maximum
7 Days
7 Days
3 Days
Drying and recoating times are related to the film thickness, temperature, the relative humidity of the air and ventilation
Surface Preparation
All surfaces must be clean, dry, and free from grease, oil, laitance, dust and other contamination
Bare Concrete:
Remove dirt and contamination by detergent washing, flame cleaning or other appropriate means
For the best long term coating life, laitance should be removed by vacuum blast cleaning (recommended), power grinding or acid etching
If acid etching, more than one application may be required to produce a granular surface suitable for good adhesion
Vacuum blast cleaning should produce a surface profile appropriate to the thickness of the coating being applied
If laitance is not removed, it can detach in service along with the coating, leaving patchy areas of bare concrete
Previously Painted Floors:
Abrading (as well as thoroughly cleaning) the existing coating is always recommended to optimise adhesion
A test area is recommended to confirm that adequate adhesion can been achieved and that the previous coating is not attacked
Wood Floors:
Punch all nail heads down below the surface
Sand the surface down to clean, smooth wood using an industrial vacuum sander, cutting-in at edges with a hand sander
To give a smooth finish it is recommended to also lightly sand and vacuum between coats
Steel Floors:
Please consult Axalta Coating Systems or Rawlins Paints Technical Department on 0113 2455450 (option 2) or send a message to [email protected] for advice
Mixing
Mixing Ratio:
Base 09FAQ - 3 parts by volume
Hardener 09FAQ-ACT - 1 part by volume
Notes:
Mix only in the proportions stated, mixing each component individually then together using a mechanical agitator
Agitate periodically during use to ensure product remains homogeneous
The concrete surface must be dry and at least 12 weeks old
The moisture content of the concrete should not exceed 6% when measured 25mm below the surface (with e.g. a Protimeter measuring in 25mm drilled holes filled with gel), or 14% when measured with a surface moisture gauge (such as a Protimeter WME (Wood Moisture Equivalent) gauge)
Only apply in conditions of good ventilation which must be maintained during drying and curing
Do not apply when rain, mist, sleet or snow are imminent
During application and drying time of the paint coating, the surface should be dry, the relative humidity should not exceed 85% and the steel temperature should remain at least 3°C above the dew point
Only apply this product when the above conditions can be maintained throughout the critical application and drying/curing process
Paint temperature should ideally be at a minimum of 15ºC
Application Methods
Designed for brush or roller application. A short pile head is recommended for rollering
Dampen brush and roller head before applying. Thin with up to 10% clean water if required
Prime bare concrete areas by thinning the first coat with up to 10% with clean water to act as a sealer coat
Two full coats are recommended over sealed concrete or previously painted surfaces
For anti-slip properties, after sealing or over previous intact and prepared coatings, apply one unthinned coat and sprinkle with an aggregate of suitable size to achieve required degree of anti-slip properties. When dry, sweep off excess aggregate and apply a further full coat to seal in the aggregate
Do not apply or cure below 7ºC; temperatures above 10ºC are recommended and above 15ºC is preferred
Like all epoxy coatings, this product will chalk on prolonged exterior exposure, the degree of which is subject to atmospheric conditions
Health & Safety
Containers are provided with safety labels which should be observed
Further information about hazardous influences and protection are detailed in individual Product Safety Data Sheets
For specific advice regarding any aspect of this product, please consult our Technical Department on 0113 2455450 (option 2) or send a message to [email protected]
Product Details
5336-874843
Data sheet
Manufacturer
Axalta Coating Systems
Water / Solvent Based
Water
For Use On
Concrete, Wood, Stone, Tile
Application Method
Brush, Roller
Sheen
Semi-Gloss
Colour
Standard / Ready Mixed
Single, Two or Three Pack
Two-Pack
Product Certifications
Conforms to Category (j) of Directive 2004/42/EC, which carries a VOC limit of 140g/l
Pack Size
5L
Mixing Ratio
Base 3 parts by volume : Hardener 1 part by volume
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.
Axalta Floorcote AQ200 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
Axalta No. 5 Thinner, for use with the Axalta range of coatings, has a specially formulated blend of solvents designed to mix with its compatible paint/coating to create an optimal consistency for application whether it be for brush, roller or spray.
Can also be used for the cleaning of some surfaces prior to application of the coating...