Rust-Oleum 5090 Anti-Condensation Coating is a water absorbing coating to be used on ceilings and the upper parts of walls, where steam or water vapour formation occurs, in order to prevent condensation and dripping. It is intended as a one coat, airless application, but a more textured finish can be obtained by applying 2-3 coats by brush or roller.
Protects against discontinuous steam or water vapour formation
Ideal for breweries, kitchens, wash and shower rooms
1 Litre product will, after drying, absorb at least 400 grams of water
Rust-Oleum 5090 Anti-Condensation Coating is a water absorbing coating for ceilings and upper walls, preventing condensation and dripping
Water-based
Recoatable after just 5 hours
Application is possible on slightly damp surfaces
Ideal for high humidity areas (breweries, wash and shower rooms, etc.)
Stops walls and ceilings dripping from condensation
This off-white, anti-condensation paint should be used on ceilings and walls, and is intended for one coat application by airless spray. Rust-Oleum 5090 can be used where steam or water vapour formation occurs, in order to prevent condensation and dripping.
1 litre of product will, after drying, absorb at least 400 grams of water!
Old coatings should be humidity resistant. For advice on primers, please contact Rawlins Paints Technical on 0113 2455450 (option 2) or send a message to [email protected]
Technical Data
Density: 1,22
Gloss Level: Matt
Solids content in volume: 27 %
Heat Resistance: 50°C (dry heat)
Drying Time At 20°C/RH 50%
Drying Times
Touch dry:
1 hour (20°C)
6 hours (10°C)
1 hour (30°C)
Dry to handle:
2 hours (20°C)
8 hours (10°C)
2 hours (30°C)
Dry to recoat:
5 hours (20°C)
48 hours (10°C)
4 hours (30°C)
Fully cured:
3 days (20°C)
6 days (10°C)
2 days (30°C)
Theoretical Consumption
1,35 m²/l
Recommended wet film thickness: 740 µm
Recommended dry film thickness: 200 µm
Practical Consumption
Practical coverage depends on many factors such as porosity and roughness of the substrate and material losses during application.
Approvals
Absorption by Ceripec.
Please contact Rawlins Paints' Technical Support Team on 0113 2455450 for more information.
Product Details
5090.5
Data sheet
For Use By
Professional Use
For Use By
Industrial Use
Interior / Exterior Use
Interior
Water / Solvent Based
Water
For Use On
Concrete, Brick
Application Method
Brush, Roller, Spray
Sheen
Matt
Colour
Standard / Ready Mixed
VOC Levels
Low (50-149 g/l)
Single, Two or Three Pack
Single
Pack Size
5L
Application
Brush, Roller, Spray
Dry to Handle (at 20°C)
2 Hours
Dry to Recoat (at 20°C)
5 Hours
Fully Cured (at 20°C)
3 Days
Coverage
1.35m² per litre
Max. Application Temperature
35°C
Min. Application Temperature
5°C
Density
1,22
Heat Resistance (up-to)
50 °C (dry heat)
VOC
57 g/l
Shelf Life (from date of manufacture)
4 years from date of production in unopened cans, if stored in dry, well ventilated areas, not in direct sunlight at temperatures between 5° and 35°C. Keep from freezing. Freezing will irreversibly affect the product
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.
Is this product suitable for application to the underside of a corrugated iron shed roof?
Answer from Rawlins’ Technical Team:
Yes, assuming the surface is bare metal, after preparation (see product data sheet) apply Rust-Oleum Mathys Metal Cladding Primer followed by Rust-Oleum 5090 Anti-Condensation Coating.
Please note that Rust-Oleum 5090 Anti-Condensation Coating works in an environment where there is short term high humidity followed by longer periods when humidity can escape e.g. bathrooms. It cannot work where the humidity builds up and cannot then escape. So if this shed was closed and humidity built up a as a result of sunshine, you would still get condensation forming and then dripping down from ceiling.
Rust-Oleum Mathys Metal Cladding Primer is a water based primer specially designed for application on weathered metal cladding to provide a perfect base for Rust-Oleum Mathys Metal Cladding Topcoat, also suitable for bare or blasted steel, galvanized steel, zinc and aluminium.
Single pack anti-corrosion primer
Can be overcoated after just...
Rust-Oleum 9169 Epoxy Rust Primer is a low viscous epoxy rust-primer with outstanding adhesion and corrosion protection for manually derusted metals and can be recoated with Rust-Oleum 9100 topcoats.
Can be applied directly to sound rusted surfaces (less work)
Penetrates through rust onto sound metal
Contains a high amount of rust...
General Painting Application Kit from Rawlins Paints provides the basics for any painting project. Whether it is a one off job, or you just want to make sure the right application tools get to site.
Provides an economical way of making sure you will have what you need
Ideal for interior and exterior paint projects
Click to jump down to...