Sherwin-Williams Macropoxy M330

Reference:

Manufacturer:

Sherwin-Williams Macropoxy M330 (formerly known as Epigrip M330) is a 2-pack epoxy sealercoat for use over zinc silicate and other types of zinc rich primers. It is also used as a blast primer for use over stainless steel.

Bulk Buy

£58.44 tax excl.

£70.13   tax incl.

Product Description

Sherwin-Williams Macropoxy M330 (formerly known as M330) is a 2-pack epoxy sealercoat for use over zinc silicate and other types of zinc rich primers. It is also used as a blast primer for use over stainless steel.

Recommended Primers & Topcoats

  • Zinc Clad J984 Zinc Rich Primer
  • Dox-Anode D5V2

Indefinitely overcoatable with epoxy systems provided the surfaces to be coated have been suitably cleaned. Where a high degree of gloss and colour retention is required, overcoat with Acrolon C137V2, Acrolon C237 within 7 days at a minimum dft of 50 microns or in the case of Accrolon C750V2 overcoat within 4 days. These overcoating times refer to achievement of optimum adhesion at 23°C and will vary with temperature.

For overcoating with alkyd systems consult Technical Team for advice. 

Application Conditions & Overcoating

Epoxy paints should preferably be applied at temperatures in excess of 10oC. In conditions of high relative humidity, ie 80-85% good ventilation conditions are essential. Substrate temperature shall be at least 3oC above the dew point and always above 0°C.

At application temperatures below 10°C, drying and curing times will be significantly extended, and spraying characteristics may be impaired.

Application at ambient air temperatures below 5°C is not recommended.

In order to achieve optimum water and chemical resistance, temperature needs to be maintained above 10oC during curing.

If it is desired to overcoat outside the times stated on the data sheet, please seek advice from Technical Team.

Additional Notes

Drying times, curing times and pot life should be considered as a guide only.

The curing reaction of epoxies commences immediately
the two components are mixed, and since the reaction is dependent on temperature, the curing time and pot life will be approximately halved by a 10°C increase in temperature and doubled by a 10°C decrease in temperature.

When M330 is used as a tie-coat or sealer coat over inorganic zinc silicate, the zinc silicate must be left for a minimum of 16 hours at 15°C and then checked for cure. Prior to overcoating, the inorganic zinc silicate primer must be fully cured.

Care must be taken to ensure that Macropoxy M330 is not over-applied on to the zinc silicate otherwise there is a possibility of pinholing occurring. 

Epoxy Coatings - Tropical Use

Epoxy paints at the time of mixing should not exceed a temperature of 35°C. At this temperature the pot life will be approximately halved. Use of these products outside of the pot life may result in inferior adhesion properties even if the materials appear fit for application. Thinning the mixed product will not alleviate this problem.

The maximum air and substrate temperature for application is 50°C providing conditions allow satisfactory application and film formation. If the air and substrate temperatures exceed 50°C and epoxy coatings are applied under these conditions, paint film defects such as dry spray, bubbling and pinholing etc. can occur within the coating.

Numerical values quoted for physical data may vary slightly from batch to batch. 

It is your responsibility to read the Product Data Sheets (available below) before you place an order and prior to application of the product. The content of this website is our best recommendation and is not advice. Coverage rates quoted are approximate, you agree that coverage depends on the condition of the substrate, surface absorption, texture and application method. We ALWAYS recommend a trial area is coated to ensure the product meets your requirements before use.

Technical Data

Typical Coverage (per coat)18.8m² per litre
Touch Dry10 minutes
ApplicationSpray
The figures stated above are approximate. Please ensure you refer to all datasheets for full application information.

Download

Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions



Be the first to ask a question about this product!

Question about the product

* Required fields
Send

The question has been correctly sent

Free delivery

On orders over
£75.00 + VAT

Low trade prices

Our best trade prices on everything!

Technical Advice

Fast FREE Technical Advice for Products & Projects

Click & collect

Order and collect from
our Leeds based trade store.
silent-exothermic unable