Rust-Oleum B95 High Build Flexible Epoxy

Manufacturer:

Rust-Oleum B95 High Build Flexible Epoxy is a two pack epoxy for hand cleaned, blasted, primed or galvanised steel, concrete and brickwork with outstanding corrosion, wear and impact resistance. Rust-Oleum B95 High Build Flexible Epoxy is an epoxy coating with the advantages of an elastic paint that moves with the structure to stop cracking or peeling.

Bulk Buy

£245.09 tax excl.

Available colours:

Product Description

Rust-Oleum B95 High Build Flexible Epoxy is based on two-component, modified low molecular epoxy resins and is practically solvent free. Designed for application on concrete, masonry, and hand tool prepared, blasted, primed or galvanized steel. Primarily intended for airless spray application but may also be applied by brush and roller.

Features & Benefits

  • Flexible, high build epoxy for metal and concrete
  • Excellent corrosion, wear and impact resistance
  • Resistant against humidity and moisture
  • Remains flexible to prevent cracking and peeling
  • Virtually solvent free and low odour
  • Twice as thick as regular epoxies (150μm dry)

Rust-Oleum B95 High Build Flexible Epoxy offers appropriate corrosion resistance in severe industrial and coastal exposures; high humidity and moisture conditions. Rust-Oleum B95 High Build Flexible Epoxy is, due to its flexibility, especially suitable for concrete and steel floors showing good abrasion and impact resistance; porous substrates should first be primed with Rust-Oleum 5401 Epoxy Impregnation Primer; very dense substrates, like ceramic tiles, should be primed with Rust-Oleum 3333 Super Adhesion Primer.

Rust-Oleum B95 High Build Flexible Epoxy can be applied directly on properly prepared steel or galvanized steel, on itself, on Rust-Oleum 9170 Epoxy Metal Primer, Rust-Oleum 9180 Epoxy Metal Primer or Rust-Oleum 9169 Epoxy Rust Primer. This product is also suitable for application on old, reversible coatings such as Chlorinated Rubbers, Vinyls, etc. If good U.V. and/or chemical resistance is required Rust-Oleum 9600 Rust-O-Thane Polyurethane should be applied.

Surface Preparation
Remove grease, oil and all other surface contamination by alkaline or high pressure (steam) cleaning in combination with appropriate detergents. Sand intact coatings to roughen the surface slightly. Check compatibility, especially when applied on reversible coatings, the application of a test-patch is strongly recommended. The surface must be clean and dry during application.

Concrete and masonry: New concrete or masonry should cure and dry for at least 30 days before applying the coating system. Remove laitance, any loose or unsound concrete or deteriorated coatings. Smooth concrete should be roughened. Remove curing compounds.

Steel: Remove loose rust, mill scale and deteriorated coatings by hand or power tool cleaning to St 2/3 (ISO 8501-01 : 1988). Large areas may be thorough blast-cleaned to Sa 2 (ISO 8501-01 : 1988), blast profile max. 50μm.

Directions for Use
Stir individual components thoroughly before mixing them together. Use the boxing method or use a low speed mixer.

  • Mixing ratio: base (B95): activator (9501) = 1 : 1 by volume.
  • Induction time: 15 minutes for a 10 litre. mix at 20°C.
  • Pot-life: 45 minutes for a 10 litre. mix at 20°C.
  • Dilution with at least 10% Thinner 160 extends pot-life 30 minutes.

Application & Thinning

  • Brush: 10 to 15 vol.%; Rust-Oleum Thinner 160. Use natural bristles, long hair brushes.
  • Roller: 10 to 15 vol.%; Rust-Oleum Thinner 160. Use medium nap polyamide (perlon 16-20mm.) rollers. Roller application requires 2 coats to achieve recommended d.f.t.
  • Airless spray: 5 to 15 vol.%; Rust-Oleum Thinner 160. Pneumatic and electric airless equipment. Tip size: 0.015-0.025 inch. Fluid pressure: 250 - 300 bar.

Cleanup: Use Rust-Oleum Thinner 160. Preferably use disposable brushes and/or rollers.

Application Conditions
Temperature of air, substrate and coating material between 10 and 35°C and relative humidity below 85%. The substrate temperature must be at least 3°C above dew point. Maximum dry film thickness per coat: 500μm dry, equals 505μm wet.

It is your responsibility to read the Product Data Sheets (available below) before you place an order and prior to application of the product. The content of this website is our best recommendation and is not advice. Coverage rates quoted are approximate, you agree that coverage depends on the condition of the substrate, surface absorption, texture and application method. We ALWAYS recommend a trial area is coated to ensure the product meets your requirements before use.

Technical Data

Typical Coverage (per coat)6.6m² per litre
Touch Dry8 Hours
ApplicationBrush, Roller, Spray
The figures stated above are approximate. Please ensure you refer to all datasheets for full application information.

Download

Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

Questions



Be the first to ask a question about this product!

Question about the product

* Required fields
Send

The question has been correctly sent

Free delivery

On orders over
£75.00 + VAT

Low trade prices

Our best trade prices on everything!

Technical Advice

Fast FREE Technical Advice for Products & Projects

Click & collect

Order and collect from
our Leeds based trade store.