Thermoguard Intumescent Mastic
    • Thermoguard Intumescent Mastic

    Thermoguard Intumescent Mastic

    THIM
    THE1286

    A one-part intumescent acrylic mastic for sealing gaps around fire doors, window frames and for sealing joints, voids and irregular holes in fire rated structures. Forms a char, preventing the passage of fire and smoke, when exposed to the heat of a fire.

    • Tested around: metallic pipes, cable trays, cable bunches, small, medium & large cables
      • In Block Wall, Concrete, Masonry & Plasterboard Partition
      • In Linear Joints up to 60mm wide
      • In large service openings up to 490 x 150mm
      • For sealing of linear joints in concrete floors, masonry walls & plasterboard including head of wall details up to 60mm
      • Suitable for flexible walls, rigid walls & floors
    Colour
    Size

    £3.86 (incl. VAT)

    £3.22 (ex. VAT)

    Quantity
    Please choose your colour
    In Stock and Available for Delivery (See Delivery Options Below)

    Description

    Thermoguard Intumescent Acoustic Mastic is a one-part intumescent acrylic mastic for sealing gaps around fire doors, window frames and for sealing joints, voids and irregular holes in fire rated structures. The sealant forms a char, preventing the passage of fire and smoke, when exposed to the heat of a fire.

    • Tested around metallic pipes, cable trays, cable bunches, small, medium and large cables
    • Tested in Block Wall, Concrete, Masonry and Plasterboard Partition
    • Suitable for flexible walls, rigid walls & floors
    • Tested in Linear Joints up to 60mm wide
    • Tested in large service openings up to 490 x 150mm
    • Tested for sealing of linear joints in concrete floors, masonry walls and plasterboard including head of wall details up to 60mm
    • Sealant remains flexible after installation
    • The mastic has been independently tested in accordance with BS476 and EN requirements - please refer to the Performance Table below
    • It has good unprimed adhesion to a wide variety of common building substrates, although it is recommended that a small area is tested on unusual substrates



    Quick Links - Click To Jump To Section:




    Features & Benefits


    • CE Marked
    • Certifire Approved
    • UL-EU Listed
    • Tested in accordance with EN 1366-3 : 2009 and EN 1366-4 : 2006
    • Fire Classification to EN 13501-2
    • Acoustic Isolation to EN 10140 to 63dB
    • Air Permeability testing to EN 1026 to 600Pa - 100Pa 0.0/0.0 m3/h/m2
    • Mechanical Adhesion and Tensile testing to EN ISO 8039 & EN ISO 9046
    • VOL-LEED 4.1 (NC-2009 IEQc4.1)
    • Tested with Metallic Pipes, Cables, Cable Bunches, Cable Trays and Cable Ladders
    • Causes no known adverse effects to plastic pipes, plastic cables, sheathing or metallic components Joint movement capabilities
    • Halogen free, resists fungi and vermin
    • Tested in Block Wall, Concrete, Masonry and Plasterboard Partition
    • Suitable for flexible walls, rigid walls & floors
    • Tested in Linear Joints up to 60mm wide
    • Tested in large service openings up to 490 x 150mm
    • Tested for sealing of linear joints in concrete floors, masonry walls and plasterboard including head of wall details up to 60mm
    • Sealant remains flexible after installation
    • The mastic has been independently tested in accordance with BS476 and EN requirements - please refer to the Performance Table below
    • It has good unprimed adhesion to a wide variety of common building substrates, although it is recommended that a small area is tested on unusual substrates



    Product Data


    General CharacteristicsInspection MethodValue
    Product Data (uncured)
    Density (S.G)ASTM D792:131.63
    Appearance Paste, matt finish
    Resistance to flowISO 7390 : 2003Pass
    Product Data (after curing)
    Hardness Shore AISO 7619-1 : 201063/39
    Movement Capability 7.50%
    Operating Temperature -5℃ to 40℃
    Loss Mass of Mass on HeatingISO 3451-1 (Method A)68.34
    Flexibility - Bend TestISO 1519Pass
    Longevity of Firestop MaterialsASTM E2923 : 1430 Years
    ConditioningEOTA TR024Type X
    Air Borne soundEN 10140-2 : 201063dB
    Other Product Details
    Shelf Life18 months shelf life from manufacture date printed on cartridge



    Fire Performance Table


    Floor & Wall Joint Size Width & DepthBackingGap Face MaterialIntegrity Rating (Mins)Insulation Rating (Mins)Linear Metres Per Cartridge
    5mm x 10mmPE Open Cell FoamAAC/AAC3003006.2
    10mm x 10mmPE Open Cell FoamAAC/AAC3003003.1
    15mm x 10mmPE Open Cell FoamAAC/AAC3003002.07
    20mm x 10mmPE Open Cell FoamAAC/AAC3003001.55
    25mm x 15mmPE Open Cell FoamAAC/AAC3002150.83
    30mm x 15mmPE Open Cell FoamAAC/AAC3002150.69
    35mm x 20mmPE Open Cell FoamAAC/AAC3002140.44
    40mm x 20mmPE Open Cell FoamAAC/AAC3002140.39
    45mm x 25mmPE Open Cell FoamAAC/AAC3002140.28
    50mm x 25mmPE Open Cell FoamAAC/AAC3002140.25
    6mm x 15mmPE Open Cell FoamAAC/STEEL300914.13
    10mm x 15mmPE Open Cell FoamAAC/STEEL300912.07
    15mm x 15mmPE Open Cell FoamAAC/STEEL300911.38
    20mm x 15mmPE Open Cell FoamAAC/STEEL300911.03
    25mm x 15mmPE Open Cell FoamAAC/STEEL300910.83
    30mm x 15mmPE Open Cell FoamAAC/STEEL300910.69
    10mm x 12.5mmPE Open Cell FoamPB/AAC1201202.9
    20mm x 12.5mmPE Open Cell FoamPB/PB1201201.45
    Small CablesNonePB/PB120120N/A
    Medium CablesNonePB/PB120120N/A
    Large CablesMMFPB/PB120120N/A
    Metallic PipesNonePB/PB120120N/A
    ** Insulation In Floor Reduces 50% , However Integrity Remains the Same **

     

    The fire resistance tests have been achieved through testing in according to EN 1366-3 : 2009 and EN 1366-4 : 2006 and are specific to the conditions of the tests. They do, however, provide a good indication of the expected performance of the sealant in fire situations. To achieve a specific fire rating, all substrates being used in the system must have equivalent fire ratings.



    Installation


    For in-depth installation guidance with depths, classification and illustrations, please download the Technical Data Sheet for the installations below:

    Installation TypePage No.
    Intu Mastic Fire Resistant Joint Through Rigid FloorPage 3
    Intu Mastic Fire Resistant Joint Through Rigid Floor And SteelPage 4
    Intu Mastic Fire Resistant Joint Through Rigid WallPage 5
    Intu Mastic Fire Resistant Joint Through Rigid Wall And SoftwoodPage 6
    Intu Mastic Fire Resistant Joint Through Flexible Wall Horizontal OrientationPage 7
    Intu Mastic Fire Resistant Joint Through Flexible Wall Vertical OrientationPage 8
    Intu Mastic Fire Resistant Loose Cable Penetration Seal Through Flexible Wall Horizontal Orientation Without Backing MaterialPage 9
    Intu Mastic Fire Resistant Loose Cable Penetration Seal Through Flexible Wall Horizontal OrientationPage 10
    Intu Mastic Fire Resistant Cable Tray & Cable Penetration Seal Through Flexible Wall Horizontal Orientation Without Backing MaterialPage 11
    Intu Mastic Fire Resistant Cable Tray & Cable Penetration Seal Through Flexible Wall Horizontal OrientationPage 12
    Intu Mastic Fire Resistant Metallic Pipe Penetration Seal Through Flexible Wall Horizontal Orientation Without Backing MaterialPage 13
    Intu Mastic Fire Resistant Metallic Pipe Penetration Seal With TDW Through Flexible Wall Horizontal Orientation Without Backing MaterialPage 14
    Intu Mastic To Seal Batt System In A Multi Penetration SealPage 15
    UL Certification Fill or Cavity Materials Certified for US & CanadaPage 16
    Intu Mastic Fire Rated Joint Through Concrete Floor / Concrete Assembly Head Of WallPage 17
    Intu Mastic Fire Rated Joint Through Lightweight PartitionPage 18
    Intu Mastic Fire Rated Joint Through Concrete Wall / Concrete Wall AssemblyPage 19
    Intu Mastic Fire Rated Joint Through Concrete Floor / Lightweight Partition Assembly Head Of WallPage 20
    Durability and ServiceabilityPage 21
    Certifire, Intu Mastic EN 1366-4 Approval MatrixPage 22
    Typical Details Of Flexible Wall Gap Using Intu Mastic With Pe Backer RodPage 27
    Typical Vertical Section Showing Use Of The Intu Mastic In A Blockwall With A Cable TrayPage 28
    Blockwork To Column Gap Using Intu Mastic With Pe Backer RodPage 29
    Blockwork To Column Gap Using Intu Mastic With Pe Backer RodPage 30
    Blockwork To Column Gap Using Intu Mastic With Pe Backer RodPage 31
    SRL Data SheetPage 32

     

    General Product Description

    Intu Mastic is an acrylic based sealant used to reinstate the fire resistance performance of wall and floor constructions where they have been provided with apertures for the penetrations of multiple services and to form linear gap seals where gaps are present in wall and floor constructions and linear joints where wall and floor constructions abut.

    Intu Mastic has slight intumescent properties that cause it to swell on heating.

    The sealant is gunned or trowelled into the aperture in or between the separating elements/elements to a specific depth utilising various backing materials.

    A polyethylene backing rod can be utilised as a depth gauge. Reaction to Fire classification ‘F’

    The Intended use of system Intu Mastic is to reinstate the fire resistance performance of gaps in and joints between rigid and flexible wall constructions, gaps in and joints between rigid floor constructions.

    The specific elements of construction that the system Intu Mastic may be used to provide a gap or joints seal in, are as follow:

     

    Rigid Floors

    The floor must have a minimum thickness of 150mm and comprise concrete, aerated concrete or masonry, with a minimum density of 650kg/m3.

     

    Rigid Walls

    The wall must have a minimum thickness of 100mm and comprise concrete, aerated or masonry, with a minimum density of 650kg/m3.

     

    Flexible Walls

    The wall must have a minimum thickness of 100mm and comprise timber or steel studs lined on both faces with minimum 2 layers of 12.5mm thick, ‘Type F’ Gypsum boards according to EN 520. In timber stud walls, no part of the penetration shall be closer than 100mm to a stud, the cavity must be closed between the penetration seal and the stud and minimum 100mm of insulation of class A1 or A2 according to EN 13501-1, is provided within the cavity between the penetration seal and the stud.

    Intu Mastic is required to seal all joints and junctions during the sealing process of Batt. Coated Batt are 50mm thick and supplied in overall dimensions 1200mm x 600mm with a density 140kg/m3 and is subject to a separate ETA referenced 14-0099.

    The Supporting construction must be classified in accordance with EN 13501-2 for the required fire resistance period.

    The system Intu Mastic may be used to provide a linear joint or gap seal with specific supporting constructions and substrates and as a penetration seal.

    The maximum permitted joint/gap width for system Intu Mastic is 50mm. The maximum movement capability of system Intu Mastic is ≤ 7.5%

    Intu Mastic has been tested in accordance with EOTA Technical Report - TR024 - Edition November 2006, for the type Z1, use category specific in ETAG 026-3 (used as European Assessment Document, EAD). The results of the tests have demonstrated suitability for Penetration Seals and Linear Gap Joints.

    Type Z : Intended for use In internal conditions with humidity equal to or higher than 85% RH excluding temperatures below 0℃, without exposure to rain or UV.

     

    Air Permeability

    System Intu Mastic has been tested in accordance with BS EN 1314-1 to provide the following results:

    Product testedIntu Mastic intumescent sealant
     Results under positive chamber pressureResults under negative chamber pressure
    Pressure (Pa)Leakage (m3/h)Leakage (m3/ m2/h)Leakage (m3/h)Leakage (m3/m2/h)
    500.60.81.11.5
    10011.41.31.8
    1502.83.91.52.1
    2003.85.31.92.6
    2504.56.322.8
    30056.92.43.3
    4505.17.11.92.6
    6006.79.32.23.1

     

    Airbourne Sound Insulation

    Acoustic Rating BS EN ISO 10140-3:1995Rw(C;Ctr) :38(-2;-7) dB



    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and ConditionsWe will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

    Product Details
    1286-282892

    Data sheet

    Manufacturer
    Thermoguard
    For Use By
    Professional Use
    Single, Two or Three Pack
    Single
    Suitable For Use On
    Floors
    Suitable For Use On
    Cables
    Suitable For Use On
    Walls
    Suitable For Use On
    Pipes
    Suitable For Use On
    Metallic Pipes
    Application Method
    Sealant Gun
    Product Usage Type
    Sealer
    Fastest Delivery
    Next Working Day
    Colour Family
    White
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Thermoguard Intumescent Mastic is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT