• Nullifire SC802 On-Site Water-Based Intumescent Basecoat

    Nullifire SC802 On-Site Water-Based Intumescent Basecoat

    342812
    NUL2230

    A water-based, white, thin film intumescent coating for the protection of internal structural steelwork. Nullifire SC802 can provide up to 60 minutes fire resistance. 

    Please Note: We strongly recommend Tricomb Plastic Wet Film Gauges are used to help ensure correct film thicknesses are achieved during application

    Colour
    Size
    Finish

    £164.80 (incl. VAT)

    £137.33 (ex. VAT)

    Quantity
    Please choose your colour
    In Stock and Available for Delivery (See Delivery Options Below)

    Description

    Nullifire SC802 can be applied to a smooth matt finish. A compatible top-seal can be applied if a decorative finish is required.

    Features & Benefits

    • Water based intumescent coating suitable for internal use on structural steelwork for up to 60 minute fire resistance
    • “Next generation” product - with greater efficiency on site
    • Compatible with a full range of Nullifire primers and top seals
    • Very low VOC

    Surface Preparation & Priming

    • SC802 should be applied onto a clean, undamaged, dry and primed steel surface.
    • Certain types of primers can cause char adhesion problems in a fire. In particular, thermoplastic primers must be avoided.
    • Nullifire recommend and have tested PM015 and PM020 primers.
    • Nullifire have carried out compatibility testing on a wide range of primers. Contact our technical team for details on compatibility.
    • SC802 should not be applied directly to galvanised surfaces or zinc rich primer.
    • The primer must be applied in accordance with the manufacturer’s instructions.
    • Nullifire should be consulted for technical advice when zinc rich primers or the overcoating of existing paints are specifed for use.

    Application Conditions

    • Nullifire SC802 is recommended for application and use on dry protected structural steel only.
    • If the basecoat is allowed to get wet, it is likely to be damaged – blistering and wrinkling may occur.
    • SC802 should only be applied when the air and steel temperatures are above 5°C. Relative humidity should be below 80% for successful application. Steel surface temperature should be a minimum of 3°C above the dew point.
    • Ensure the steel is dry and free from contact with rain or condensation during the application and drying of SC802.



    Optifire+: Reliable and traceable fire protection


    Optifire+ is a unique addition to Nullifire intumescent steel coatings that provides full transparency for:

    • Applicators – Ability to ensure product installed on site is correct and to standards
    • Main Contractors - Ability to ensure that specifications are been adhered to
    • Architects and Specifiers - Ensuring your design projects comply to the latest building regulations and fire protection that is identifiable in future years



    What is Optifire+ and how does it work?


    Optifire+ is a unique and impossible to manipulate pigment. With Optifire+ we can be sure, at any time after the project is completed, that the product specified is the product applied – confidence that the materials submitted through the approval processes are installed to protect customer's assets.

    Optifire+ is invisible to the naked eye and is added to Nullifire intumescent steel coatings. It can be identified with the traceability tool.



    Why it’s important


    As a product identifier, Optifire+ doesn’t change the way intumescent coatings work. But it does stimulate that they are used and are applied correctly. Nullifire intumescent steel coatings can’t be altered without it being visible and application can be checked afterwards.

    With Optifire+, Nullifire goes beyond what’s expected and further endeavors to keep residents and emergency services safe, and protect the buildings that they rely on.

    Optifire+ is manufactured within the UK. These locally produced products are independently tested and certified according to the highest standard in the industry.



    Legal


    Building owners are now more than ever been urged to act and put the safety of residents first. There’s an increased focus and scrutiny on the effectiveness of fire protection strategies in commercial and residential buildings. Negligence or simply being unable to prove that the proper precautions have been taken means risking legal action.

    IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.

    Product Details
    2230-455309

    Data sheet

    Interior / Exterior Use
    Interior Use
    Single, Two or Three Pack
    Single
    Application
    Brush, Roller, Spray
    Coverage
    1,000 g/m² based on an applied 0.5 mm dry film thickness
    Touch Dry
    3 Hours
    Base Type
    Water-Based
    Suitable For Use On
    Structural Steel
    Finish
    Matt
    Application Method
    Brush
    Application Method
    Spray
    Application Method
    Roller
    Product Usage Type
    Basecoat
    Fastest Delivery
    Next Working Day
    Colour Family
    White
    Fire Rating
    60 Minutes
    Fire Rating
    30 Minutes
    Site Application
    On-Site
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    questions Thomas O'Neill  on 2023-02-10 11:52:10
    Question: 

    Hi could you work how much paint I will need of this product 203x203x46UC 5.5metre 203x103x23UB 3 metre 3 sides No topcoat as it's going to white anyway . Kind regards Tom

    Answer from Rawlins’ Technical Team: 

    Thank you for the enquiry, we have contacted you directly by email.

    questions Michael Muldoon  on 2022-05-05 21:46:46
    Question: 

    Can you thin this product?

    Answer from Rawlins’ Technical Team: 

    No, this product should not be thinned.

    questions Steven Storey on 2021-11-12 12:47:25
    Question: 

    How many sq/m does 1tin of Nullifire sc802 cover?

    Answer from Rawlins’ Technical Team: 

    Intumescent paints like this do not have a specific coverage rate, the level of fire protection required and the steel dimensions will dicate the quantity required.

    We can assist with a specification for the steels we would require the information below sent to [email protected]

    - Level of fire protection required (i.e. 30, 60, 90min, etc.)

    - Each steel section dimension (i.e. 254x146x37 UB)

    - Quantity and length of each section (or overall meterage for each section)

    - Orientation (horizontal or vertical)

    - Number of sides to be painted (all sides, 3 sides, 1 flange, etc.)

    - Structural Steel Design Code (i.e. EuroCode, BS5950, BS476; Part 21, etc.)

    - Building type (i.e. office, domestic, storage, etc.)

    - Environment (internal, external, car park, chemical exposure, etc.)

    - Application on site or in shop

    Alternatively you can just forward us drawings, fabrication/cutting lists and we'll extract the information from them but in that instance we'd need some guidance as to what to allow for i.e. all steels on first floor, etc.

    questions Darran nixon  on 2020-01-02 16:12:48
    Question: 

    once i have applied the base coat with the 60 minute fire rating can i use a water base eggshell on top for colour purpose ?

    Answer from Rawlins’ Technical Team: 

    We can only recommend that you apply a Nullifire compatible topcoat such as Nullifire TS816 or Nullifire TS134 over SC802 as these have been tested to ensure in the event of the fire they don;t cause any issue for the intumescent paint.

    questions Richard Bennett on 2017-04-26 09:22:11
    Question: Can you confirm the dimension that needs to be allowed for expansion of 90min intumescent paint, i.e. the minimum clear dimension between the coating and any cladding, framing and associated obstructions.Many thanks.
    Answer from Rawlins’ Technical Team: 

    Expansion Gap for 90min FR would be 50mm or 50x DFT. For 60min we can reduce gap to 30mm.

      

    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    Nullifire SC802 On-Site Water-Based Intumescent Basecoat is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT


    You might also like

    Tricomb Plastic Wet Film Gauges (W2008)

    Ensures the quality control of the paint thickness while the coating is still wet. Applying too much coating can be expensive. Wet film measurements are also useful for coatings where the dry film thickness can only be measured destructively.More Information Delivery Info

    Price £0.23 (ex. VAT)

    £0.28 (incl. VAT)

    £0.23 (ex. VAT)

    In Stock and Available for Delivery

    Nullifire FC101 Intumescent Coating Repair Filler

    We no longer stock this product; In the absence of Nullifire FC101 Intumescent Coating Repair Filler, the associated base Intumescent product should be the material used for any repair requirements. Please contact our technical team on 0113 2455450 (option 2) or send a message to [email protected]. Nullifire FC101 Intumescent...

    In stock

    Surface Preparation Kits for Steel

    These surface preparation kits for steel have been created to help provide customers with an easily accessible bundle of tools to aid in the preparation of steel surfaces in accordance with ISO 8501-1 (St2/3) and SSPC (SP 2/3). Please click here for important information about these kits. Kit Contents: SET 1 (Hand Tools)1 x Rust-Oleum...

    Price £21.53 (ex. VAT)

    £25.84 (incl. VAT)

    £21.53 (ex. VAT)

    In Stock and Available for Delivery

    Nullifire PM020 Alkyd High-Build Primer

    Carboline Carbocoat 115 (replaces Nullifire PM020 High Build Alkyd Primer) is a fast-drying steel primer that provides corrosion protection on structural steel. Well suited for fabrication shops that need fast cure to dry and handle times.Rapid cure and fast-drying VOC compliant for most areas Good for filling properties on rough and...

    Price £56.76 (ex. VAT)

    £68.11 (incl. VAT)

    £56.76 (ex. VAT)

    In Stock and Available for Delivery

    Nullifire PM015 - Aluminium Epoxy Primer

    Carboline Carbomastic 15 LT (replaces Nullifire PM015 Aluminium Epoxy Primer) is a two-component, high build coating with excellent adhesion to rusted steel and most aged coatings.Surface tolerant Recommended for painting over rusted steel where hand cleaning only is possible Carbomastic 15 LT penetrates through rust to steel substrate...

    Price £99.24 (ex. VAT)

    £119.09 (incl. VAT)

    £99.24 (ex. VAT)

    In Stock and Available for Delivery