Sika MonoTop 615 is an R3 Classification, One-Component, Cementitious, High Build Concrete Repair and Reprofiling Low Density Mortar, particularly suited to overhead and vertical repairs.
Low density for ease of use
For repairing all types of structures
Hand applied repairs
Repairs requiring mechanical (spray) application
For exterior and interior use
For all Class R1, R2 and R3 repairs
Pre-bagged for consistency and quality
Just add water
Contains waste materials for improved sustainability
Especially suitable for substrates with low strength and for lightweight concrete
Low-shrinkage curing
Incorporates sulphate-resistant cement
High frost and deicing salt resistance
Conforms to the requirements of EN 1504-3 R3 Classification
Limitations
Refer to the recommendations provided in EN 1504- 10
Avoid application in direct sun and/or strong wind
Do not add water over recommended dosage
Apply only to sound, prepared substrate
Do not add additional water during the surface finishing as this will cause discolouration and/or cracking
Protect freshly applied material from freezing
Substrate Quality/Pre-Treatment
Concrete:
The concrete shall be thoroughly clean, free from dust, loose material, surface contamination and materials which reduce bond or prevent suction or wetting by repair materials
Delaminated, weak, damaged and deteriorated concrete and where necessary sound concrete shall be removed by suitable mechanical or very high pressure waterblasting techniques
Tying wire fragments, nails and other metal debris embedded in the concrete should be removed wherever possible
The edges where concrete is removed should be cut at a minimum angle of 90° to avoid undercutting and a maximum angle of 135° to reduce the possibility of debonding with the top surface of the adjacent sound concrete and should be roughened sufficiently to provide a mechanical key between the original material and Sika Repair material
Ensure sufficient concrete is removed from around the full circumference of the reinforcement to allow application of the reinforcement corrosion protection coating (if required) and compaction of the repair material
Steel Reinforcement:
Rust, scale, mortar, concrete, dust and other loose and deleterious material which reduces bond or contributes to corrosion shall be removed
Surfaces shall be prepared using abrasive blast cleaning or high pressure waterblasting techniques to a minimum standard of SA 2 (ISO 8501-1)
Where exposed reinforcement is contaminated with chloride or other material which may cause corrosion, the reinforcement shall be cleaned by low pressure waterblasting before application of reinforcement corrosion protective coating
Reference shall be made to EN 1504-10 for specific requirements
Mixing:
Sika MonoTop-615 can be mixed with a low speed (< 500 rpm) hand drill mixer, or for machine application, using a force action mixer with 2 to 3 bags (or more) at once, depending the type and size of mixer
In small quantities, Sika MonoTop-615 can also be manually mixed
Pour the recommended water in a suitable mixing container
While stirring slowly, add the powder to the water and mix thoroughly at least for 3 minutes adding additional water during the mixing time if necessary to the maximum specified amount and adjust to the required consistency
Application
Bonding Primer:
On a well prepared and roughened substrate, a bonding primer is generally not required for this Product
When a bonding primer is required, refer to the Product Data Sheet (see 'data sheets' tab above) for compatible Sika Products and refer to the relevant Product Data Sheet(s) for instructions
A small amount of Sika MonoTop-615 can also be mixed slightly wetter than normal and used as a scratch coat to fill any deep cavities or pits in the base of the substrate
Any bonding primer shall be applied on a pre-wet substrate and subsequent application of the scratch coat / repair mortar shall be applied 'wet-on-wet' onto the bonding primer
Repair Mortar Application:
Sika MonoTop-615 can be applied either manually using traditional techniques, or mechanically using wet spray equipment
Thoroughly pre-wet the prepared substrate a recommended 2 hours before application
Keep the surface wet and do not allow to dry
Before application, remove excess water e.g. with a clean sponge
The surface shall have a dark matt appearance without glistening, and surface pores and pits shall not contain water
When manually applying, first make a scratch coat by firmly scraping the repair mortar over the base of the substrate surface to form a thin layer and fill any deep cavities
Ensure the whole surface to be repaired is covered by the scratch coat
For vertical applications, build up layers from bottom to top by pressing mortar well into the repair area
The surface can be finished according to the surface texture requirements using a float
Do not overtrowel as this may lead to surface cracking
Curing Treatment
Protect the fresh mortar immediately from premature drying for a minimum of 3 days using an appropriate curing method (e.g. curing compound, moist geotextile membrane, polythene sheet, etc.)
Curing compounds shall not be used when they adversely affect subsequently applied Products and Systems
Reference shall also be made to EN 1504-10 for specific requirements
Cleaning of Tools
Clean all tools and application equipment with water immediately after use
Hardened material can only be mechanically removed
Product Details
1486-81342
Data sheet
Manufacturer
Sika
Interior / Exterior Use
Interior & Exterior
For Use On
Concrete Reinforced Concrete
Application Method
Spray Trowel
Single, Two or Three Pack
Single Pack
Pack Size
25KG
Density
Fresh mortar density: ~1.65 kg/L Hard mortar density after 28 days: ~1.89 kg/L
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.
I am looking to repair 'spalled' concrete paths. Is this product designed to do that? Or do you have another, or better product you can recommend. The product needs to be weather/frost resistant. Thanks in anticipation. Best wishes Gordon
Answer from Rawlins’ Technical Team:
Assuming the concrete is clean, dry, sound and prepared as detailed in the Technical Data Sheet we can recommend Rust-Oleum 5180 Epoxy Repair Mortar.
Sika MonoTop 615 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
Sika MonoTop 614F is a cement based, one component flowable repair mortar (High Flow) containing shrinkage compensators and high range water-reducing agents, meeting the requirements of Class R4 of BS EN 1504-3.
Ideal for use on horizontal or vertical repairs, bridges, marine structures, tunnels, buildings, etc. For interior and exterior use...
Use Sika MonoTop 630 Rapid (previously Sika Rapid Repair Mortar) to repair all types of structures internally and externally, horizontally and vertically. Part of the Sika Mortar System, the mortar repair is great for hand-applied repairs, for floor slabs and car parks decks, and in place of R1, R2 & R3 mortars.
Features and Benefits...