Follow us on:

    RSL Acrydur TC01 High Performance Flooring

    RSL Acrydur TC01

    TC01
    RSL10214

    A solvent free, low viscosity, Methyl Methacrylate (MMA) clear resin top coat for Acrydur flooring systems typically installed in dry areas. As a clear coat the product is ideal for top coating decorative coloured flakes and coloured quartz surfaces. Acrydur TC01 can be pigmented or use Acrydur TC02 for a coloured top coat.

    • Recommended for use as a clear top coat for Acrydur flooring systems, including coloured flake and quartz, in dry areas (Do not use over very elastic systems such as Acrydur ME04)
    • Rapid curing, low viscosity, very hard wearing
    • Easy to apply, good UV stability

    Colour
    Size
    Finish
    £395.02(incl. VAT)
    £329.18(ex. VAT)
    Quantity
    Please choose your colour
    This Product is Made to Order, Please Contact our Sales Team on 0113 245 5450

    No queries yet, leave the first!
    Description



    Quick Links - Click To Jump To Section:




    Features & Benefits


    • Ideal for:
      • Government and Public Sector
      • Industrial and Manufacturing
      • Education and Culture



    Surface Preparation


    New Concrete Floors: New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding, a minimum strength of 25N/mm² is required.

    Existing Concrete Floors: Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and making sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out using Acrydur RM01 and Acrydur RM02.

    Existing Floors (previously coated): All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. If the old resin flooring cannot be removed then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with the existing floor coating.

    Where Acrydur TC01 is applied to concrete surfaces, care must be taken to ensure that surface preparation is thorough but does not disfigure the surface.



    Priming/Application Conditions


    Substrates should be primed prior to the application of Acrydur TC01. Acrydur PR01, PR02 & PR03 are for priming substrates prior to the application of Acrydur flooring systems. Refer to product datasheets for different substrates. Porous substrates may require double priming. Acrydur TC01 is supplied in pails or drums. Before mixing ideally precondition Acrydur resin and the Peroxide as well as the fillers and quartz components to a temperature of approximately 15°C to 20°C.

    The application temperature should be -10°C to 35°C throughout the application and the curing period.



    Mixing


    Prior to use, stir the Acrydur to obtain an even distribution of the paraffin contained in the product. With pourable mixes, the Peroxide is the last component to be added in the mix. For mortars, add the Peroxide prior to adding the aggregate. Pour the appropriate ratio of hardening powder into the container of resin (see table below). Mix until the Peroxide is completely dissolved.

    Hardener addition % guidance

    TemperatureHardening PowderPot Life/MinutesHardening Time
    -5°C5%2560
    0°C4%1740
    10°C3%1530
    20°C2%1530
    30°C1%815

    NB: The quantity of hardening powder is always related to the amount of resin

    Hardening powder must not be added to the reactive resin and resin/filler mix until immediately before application. The hardening powder must always be stirred in and allowed to dissolve in the pure resin. The stirring time will depend on the type and the condition of the mixing equipment used and on the temperature of the material.

    For pigmentation usually 10% of Acrydur Pigment Powder is added. This should be dispersed first with the same quantity of resin and once an even homogenous mix is achieved the remaining resin can be added prior to adding the Peroxide hardening powder.



    Application


    Acrydur TC01 should be applied evenly by roller, brush and squeegee avoiding any puddles. If a squeegee is used, the surface must always be rolled with a paint roller afterwards.

    The application of the system requires consistent and even technique to ensure the prevention of any ponding and a consistent surface finish.



    Product Details
    10214-976873

    Data sheet

    Manufacturer
    RSL
    For Use By
    Professional Use
    Interior / Exterior Use
    Interior Use
    For Use On
    Concrete
    For Use On
    Floors
    Application Method
    Trowel
    Squeegee
    Roller
    Single, Two or Three Pack
    Two-Pack
    Pack Size
    25kg
    190kg
    Interior/Exterior Use
    Interior
    Mixing Ratio
    The base requires 1-5% hardening powder depending on site conditions. (see table in section ‘MIXING’)
    Coverage
    Typically 0.4-0.5 kg/m2
    Max. Application Temperature
    35°C
    Min. Application Temperature
    -10°C
    Density
    Approximately 0.99 g/cm3
    UN Number
    UN1866
    Layer Thickness
    0.3 - 0.45 mm
    Pot Life
    Around 12 minutes from mixing
    Water Absorption
    4 days: 125 mg (50 . 50 . 4 mm)
    Flashpoint
    10°C
    Base Type
    Solvent-Free
    Base Type
    MMA
    Suitable For Use On
    Concrete
    Suitable For Use On
    Floors
    Application Method
    Roller
    Application Method
    Trowel
    Application Method
    Squeegee
    Components
    2K
    Product Usage Type
    Topcoat
    Product Range
    Acrydur
    Category Guide
    FerFA Category 2/3
    Bond Strength
    1.5 MPa (Substrate failure)
    Shore D
    78 – 80 Units
    Water Vapour Transmission
    1.05 x 1011 g/cm.h.Pa
    Colour Family
    Clear
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.

    Questions

    Question about the product

    * Required fields
    (read)

    Be the first to ask a question about this product!

    This form should only be used for bulk order pricing requests, colour match options on a tintable product, or large project quotes. Please do not use this form to simply get an email copy of the quoted price on Rawlins' website.

    If you are a business or company and are looking for trade credit, please apply here: https://www.rawlinspaints.com/content/trade-account


    IMPORTANT SHIPPING & DELIVERY INFORMATION

    RSL Acrydur TC01 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT