Intumescent paint system in 4,000+ colours for interior fire rated concrete surfaces requiring an additional 30mins fire resistance - not subject to traffic.
These packs have been created to help users ensure they are purchasing sufficient product for their project. Each pack contains the correct amount of basecoat (Wallcoat) and topcoat (Thermoguard Wallcoat Smoke & Flame Retardant Topcoat) to ensure protection is achieved in line with the manufacturers recommendations to the respective area in question.
IMPORTANT - The information from the manufacturer contained within the main description below must be read and referred to your relevant authority for approval BEFORE purchase and use of this product/system.
Please note that this product CANNOT be used without first receiving a specification from our Technical Department for your project. Please see below.
Product customisation
Don't forget to save your customization to be able to add to cartPlease note that this product CANNOT be used without first receiving a specification from our Technical Department for your project. Please download and complete the 'Thermoguard Wall/Ceiling Enquiry Form' and return by email to [email protected]
If you have any questions regarding this process consult our technical department on 0113 2455450 (option 2).
Thermoguard Wallcoat 60, 90 & 120 Minute System for Concrete is a coloured intumescent paint system for interior fire rated concrete surfaces requiring an additional 30mins fire resistance - not subject to traffic. These packs have been created to help users ensure they are purchasing sufficient product for their project. Each pack contains the correct amount of basecoat (Wallcoat) and topcoat (Thermoguard Wallcoat Smoke & Flame Retardant Topcoat) to ensure protection is achieved in line with the manufacturers recommendations to the respective area in question.
4000+ colours available from RAL, BS & NCS
Each component of the packs can still be purchased individually if required here: Thermoguard Wallcoat and here: Thermoguard Wallcoat Smoke & Flame Retardant Topcoat
Pack Contents
- 10m² Pack = 1 x 5kg Wallcoat + 1 x 25m² Thermoguard Wallcoat Smoke & Flame Retardant Topcoat
- 20m² Pack = 2 x 5kg Wallcoat + 1 x 25m² Thermoguard Wallcoat Smoke & Flame Retardant Topcoat
- 30m² Pack = 3 x 5kg Wallcoat + 1 x 25m² Thermoguard Wallcoat Smoke & Flame Retardant Topcoat
- 40m² Pack = 1 x 20kg Wallcoat + 2 x 25m² Thermoguard Wallcoat Smoke & Flame Retardant Topcoat
- 50m² Pack = 1 x 20kg & 1 x 5kg Wallcoat + 2 x 25m² Thermoguard Wallcoat Smoke & Flame Retardant Topcoat
System (Interior Use Only)
To achieve 60, 90 or 120mins + BS EN Class B s1 d0 and Class 0 to sound concrete unpainted or painted with sound, firmly adhering* paint systems;
- Apply 2 coats of Thermoguard Wallcoat @ 4m² per kg/per coat
Followed by;
- 1 coat** of Thermoguard Wallcoat Smoke & Flame Retardant Topcoat Satin or Matt
**2 coats of Thermoguard Wallcoat Smoke & Flame Retardant Topcoat may be required for strong/dark colours - Thermoguard Wallcoat will be provided in a suitable undercoat shade to aid topcoat opacity unless instructed otherwise.
Hard or smooth paints must be thoroughly abraded to provide a key. Ensure surfaces are dry & free from contamination.
*Consult Technical Department for advice on adhesion tests, on 0113 2455450 (option 2) or send a message to [email protected]
Fire certificate issued upon completion FREE – apply HERE
IMPORTANT - The below information from the manufacturer must be read and referred to your relevant authority for approval BEFORE purchase and use.
In line with good common practice, we recommend that approval be sought for the use of our system, outlining our justification for the issuing of the Fire Certificate prior to the product’s use.
We issue a 120 min Fire Certificate to upgrade 90 min fire–rated concrete, 90 mins for 60 min fire-rated concrete and 60 mins to 30 min fire-rated concrete using the specification above, based on the evidence below.
Wallcoat Intumescent Paint added minimum 30 mins Fire Resistance to 10mm and 12.5mm cementitious board and to 12.5mm plasterboard in a 90 min indicative UKAS Fire Test Laboratory.
In all cases 25mm MDF was located 70mm behind the cement boards or plasterboards. Temperatures were monitored on the protected face (facing away from the furnace) of the MDF, and char damage to the side of MDF facing the plasterboard or cement board was measured following the 90 min Fire Test. Charred damage was 10 >12mm, indicating unprotected exposure to fire of 15 > 20 mins during the 90 min period. Insulation was maintained for 60 mins.
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.