- There are no more items in your cart
- Shipping Calculated at checkout
- Sub-Total(ex. VAT)(inc. VAT)£0.00£0.00
RSL Resutack PU
We no longer stock this product, but can recommend RSL Resuprime MVT as a great alternative.
We no longer stock this product, but can recommend RSL Resuprime MVT as a great alternative.
Resutack PU is ideal for wet on wet application. There is no waiting time required to tack off, making the whole process more efficient. It is principally designed to be used with other Resin Surfaces Limited (RSL) polyurethane coving systems.
Recommended Uses
- To be used with Resuthane JT40
Preparation
New Concrete Floors: New concrete must be clean, sound, dry, fully cured and surface laitance removed by vacuum enclosed shot blasting or mechanical grinding. A minimum strength of 25N/mm sq. is required.
Existing Concrete Floors: Remove all dirt, oil, grease, old paint or any other surface contaminants by vacuum enclosed shot blasting, scarifying or mechanical grinding. Fats, oils or greases must be removed by mechanical means and detergent washing and make sure all residue of detergent is washed and removed by rinsing with clean water. Local repairs should be carried out with Resupatch or Resuscreed 45.
Existing Floors (previously coated): All previous coatings and loose floor paints must be removed by mechanical preparation as described in the above section and primed as specified. If the old resin flooring cannot be removed, then please consult with our technical team for advice on intercoat adhesion and suitability, as it may not be compatible with existing floor coating.
Resutack PU can also be applied to existing coatings and to other cementitious screeds which should be clean and sound with an appropriate mechanical key for adhesion.
Priming
Open and porous substrates may require priming with Resutack PU or Resuprime PP. Resuprime NT may be used as primer on the dry substrates only with less than 75% ERH reading.
Where the relative humidity of a substrate exceeds 75% ERH, R.S. Dampshield FH should be specified and selected on the basis of hygrometer readings in accordance with BS 8203.
The number of coats to be applied is chosen in accordance with the following table:
ERH% Required Coating Thickness
75-85 1coat of R.S.DAMPSHIELD FH at 200 microns per coat
85-92 2coats of R.S.DAMPSHIELD FH at 200 microns per coat
92-97 3coats of R.S.DAMPSHIELD FH at 200 microns per coat
Resutack PU should be applied once the substrate has been primed and cured. For Further information please refer to recommended individual product data sheets.
Application
The ambient temperatures of the areas should not be allowed to fall below 15°C throughout the application and the curing period, as this could have an adverse effect on the appearance and colour of the system. Surface temperature must be above 10°C. Where possible it is recommended that the application area is heated to a minimum temperature of 15°C to allow the ambient and substrate temperature to stabilise prior to installation.
Pre-mix the base component to a uniform consistency then mix the entire contents of the base with the hardener. If a separate mixing bucket is being used for mixing, ensure all contents of both components are removed from the buckets supplied. Mix using a slow speed electric mixer for approximately two to three minutes until the two components have fully combined. The mixed unit should be applied immediately by squeegee, roller or brush with a consistent procedure. Floor areas should be cross-rolled to ensure even application and to minimise roller marks.
Coverage rates may vary depending on profile and porosity of the substrate.
Data sheet
- Application
- Brush, Roller, Squeegee.
- Coverage
- 1kg will cover 24 linear metres @ 150 microns WFT for a cove height of 150mm and a base of 100mm.
- Touch Dry
- Apply screed coating immediately.
- Brand
- RSL
Be the first to ask a question about this product!
IMPORTANT SHIPPING & DELIVERY INFORMATION
RSL Resutack PU is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
All delivery costs below are excluding VAT