Tikkurila Temafloor PU UV is a solvent-free polyurethane paint, that has excellent UV-resistance and withstands mechanical and chemical stresses. It`s also a high-solids, flexible and weather resistant two-component polyurethane coating.
Excellent resistance to UV
Silent, does not shrink or crack
Withstands mechanical and chemical stress
Self-levelling, to be applied with serrated or steel trowel
Intended to be used as a UV-resistant topcoat on Temafloor PU floors in parking decks and other areas exposed to direct sunlight
Professional use only - from the 24th August 2023, adequate training is required before industrial or professional use of this product.
Tikkurila Temafloor PU UV is a solvent-free polyurethane paint, that has excellent UV-resistance and withstands mechanical and chemical stresses. It's also a high-solids, flexible and weather resistant two-component polyurethane coating.
Temafloor PU-UV is a self-leveling paint and creates seamless smooth surface. The coating is mostly used for e.g. parking decks, footpaths and other areas exposed to abrasion and direct sunlight.
Self-levelling, to be applied with serrated or steel trowel
Intended to be used as a UV-resistant topcoat on Temafloor PU floors in parking decks and other areas exposed to direct sunlight
Technical Data
Technical Data
Tikkurila Temafloor PU UV
Volume Solids:
approx. 90%
SG:
1.4 kg / litre (mixture)
Viscosity:
n/a
Density:
1.6 to 1.7 g/cm³ - Hardener: 1.07 g/cm³
Storage Conditions:
Store away from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10). Keep container tightly closed. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Recommended storage temperature is +5°C ...+25°C
Shelf Life:
None
Pot Life:
40 minutes on substrate, abt. 20 minutes in the mixing container.
Flash Point:
>100˚C - Hardener: Closed cup: 35°C
Coverage (for a flat substrate):
Practical coverage depends on the porosity and evenness of the substrate and on the application method.
Drying Times At 23°C
Dust Dry:
After 6 hours
Light Trucking:
After 24 hours
Fully Cured:
After 7 days
Surface Preparation
New Concrete
Remove laitance by power grinding vacuum grit blasting or hydrochloric acid etching.
Choose the method best suited for the premises.
After grinding remove dust carefully with a vacuum cleaner.
Hydrochloric acid etching is carried out with diluted hydrochloric acid (1 part concentrated hydrochloric acid, 4 parts water).
Rinse with plenty of water.
Dry the surface.
Old Concrete
Remove all grease, oil, chemicals and other impurities by Maalipesu detergent.
Remove old peeling paint layer by grinding.
Choose the method best suited for the premises.
Clean out pot-holes removing all loose friable material.
Open cracks with e.g. an abrasive tool.
Remove loose material and dust.
If cementitious screed is used, check compatibility with the levelling screed manufacturer.
Application Conditions
The relative humidity of the concrete should not exceed 97%.
The temperature of the ambient air, surface or coating should not fall below +15ºC during application or drying.
Relative humidity of air should not exceed 70%
Mixing Components
Mixing Ratio
Base:
2 parts by volume
Temafloor PU UV
Hardener:
1 part by volume
008 4011
First stir base and hardener separately.
Mix the correct proportions of base and hardener thoroughly (approx. 2 minutes to get homogenous mixture) by using a low speed industrial hand drill with a paddle.
Insufficient mixing or incorrect mixing ratio will result in uneven drying of the surface, weaken the properties of the coating and risk the success of the application.
Thickness
Film thickness 0.3mm coverage approx:
2.7 m²/litre
Film thickness 1.0mm coverage approx:
0.9 m²/litre
Application
Priming:
Prime using Temafloor 400 epoxy varnish thinned 30–50% with Thinner 1029 or Fontefloor EP Primer epoxy varnish thinned about 20-50% with water.
Pour the primer onto the floor and apply as much as is needed to impregnate the concrete surface.
If necessary, repeat priming to get a non-porous surface.
A porous priming coat will result in holes and air bubbles in the finished coating.
Subsequent treatment can be carried out after 2 hours using "wet-on-wet" technique.
Asphalt floors should be primed by applying unthinned Temafloor PU with a suitable steel or rubber trowel.
Scatter sand of grain size Ø 0,1–0,6 mm on the fresh primer coat to ensure the screed adhesion and prohibit gliding of the screed.
Remove loose sand with vacuum cleaner before coating with Temafloor PU UV.
Containers are provided with safety labels, which should be observed. Further information about hazardous influences and protection are detailed in individual health and safety data sheets.
Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.
Tikkurila Temafloor PU UV is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.
Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.
Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.
Tikkurila Fontefloor EP Primer is a two-component water-borne epoxy lacquer that seals the concrete surface and provides adhesion to all Temafloor coatings and screeds, and Fontefloor paints, and can also be used for patching cracks and holes in concrete.Dries in 6 hours for overcoating Also used for priming of damp concrete with relative...
Tikkurila Temafloor 400 is a two-component solvent-free epoxy varnish. An excellent product for dust binding and priming of new and old concrete floors, especially where solventless and odourless products are needed. The lacquer can be used for patching when filled with sand.Used as a binder for Temafloor 4000 troweling screed and epoxy...