Sika Backer Rod Fire is a workable, mineral wool-based backing material wrapped with a glass-fibre yarn. Designed for fire resistant sealing in interior and exterior, horizontal and vertical joints in building structures such as walls and floors, with up to 4 hours fire resistance (EN 1366-4).
Easy to apply, it adapts to irregularities of joints; use in linear seals in fire compartments like stair cases, industrial facilities, warehouses, etc, and fire resistant joints exposed to chemicals or mechanical impact (in combination with Sikaflex PRO-3).
Sika Backer Rod Fire is used in conjunction with:
Sika now offer a Fire Stopping Solution Finder - a useful tool when needing assistance on specifying fire stopping solutions.
Quick Links - Click To Jump To Section:
Features & Benefits
- For professional use
- Workable, mineral wool-based backing material
- Wrapped with a glass-fibre yarn
- Designed for fire resistant joint sealing in horizontal and vertical building structures
- Up to 4 hours fire resistance (EN 1366-4)
- Easy to apply - Very versatile, can be combined with 3 joint sealants
- Efficient application from rolls
- Adapts to irregularities the of joints
- Used in conjunction with SikaHyflex-250 Facade or Sikaflex AT Connection
- For use by professional applicators only
- Sika now offer a Fire Stopping Solution Finder - a useful tool when needing assistance on specifying fire stopping solutions
Approvals/Standards
- EN 1366-4, up to 4 hours fire resistance
- EN 13501-2, up to class EI 240
- ETAG 026 part 3 - ETA 17/0980, up to class EI 240
- EN 13501-1, class A1
- ETA acc. EAD-350141-00-1106
Product Information
Chemical Base | Mineral fibre wool wrapped with glass fibre yarn. |
Appearance / Colour | Round profile supplied in rolls |
Shelf Life | Sika Backer Rod Fire has a shelf life of 72 months from the date of production, if it is stored in undamaged, original, sealed packaging, and if the storage conditions are met. |
Storage Conditions | Sika Backer Rod Fire shall be stored in dry conditions, where it is protected from direct sunlight and at temperatures between 5°C and 25°C. |
Density | ~250 kg/m3 |
Reaction to Fire | A1 (EN 13501-1) |
Dimensions and Ordering References
Packaging | Article Code |
---|
12mm x 50m roll | 580869 |
15mm x 50m roll | 580802 |
20mm x 30m roll | 580974 |
30mm x 30m roll | 580976 |
40mm x 30m roll | 580980 |
50mm x 25m roll | 580982 |
60mm x 25m roll | 580985 |
For joint dimensioning see ETA 17/0980 and/or method statement/application manual. Sika Backer Rod Fire must be installed at a minimum compression rate of 15 %. In order to select the correct diameter of Sika Backer Rod Fire the following table shall be respected:
Joint width | Diameter Sika Backer Rod Fire |
---|
7-10,2 mm | 12mm |
9-12,7 mm | 15mm |
12-17mm | 20mm |
16-25,5 mm | 30mm |
24-34 mm | 40mm |
32-42,5 mm | 50mm |
40-51 mm | 60mm |
Surface Preparation
The key to good sealant adhesion is a clean surface! Dusting alone may be sufficient for new porous substrates. Depending on the condition of the surface abrasion steps may be required additionally.
Application
Sika Backer Rod Fire shall be pushed into the joint with a blunt tool. To achieve maximum fire resistance between two pieces of Sika Backer Rod Fire and in corners, Sika Backer Rod Fire must be tightly fitted in the joint.
Once Sika Backer Rod Fire is in place, the remaining joint gap has to be sealed with SikaHyflex-250 Facade or Sikaflex AT Connection.
For information regarding joint dimensions and fire rating classes see EN 13501-2 assessment report and/or ETA 17/0980.
Application of Sika Backer Rod Fire
Application of Sealant
The application of Sikaflex PRO-3, SikaHyflex-250 Facade or Sikaflex AT Connection on Sika Backer Rod Fire is not different from the application on a standard PE backer rod. As the application of Sika Backer Rod Fire may have left some fibres on the substrate a short dust-removal step may be required.
IMPORTANT: The sealant must fill the entire joint or cavity and be in full contact with the joint sides. If the joint is improperly filled, good adhesion will not be achieved, and the joint’s performance will be weakened.
Resistance to fire of vertical linear seals in rigid walls*
(wall thickness ≥ 150 mm) sealed with Sika Backer Rod Fire combined with SikaHyflex-250 Facade, Sikaflex AT Connection or Sikaflex PRO-3. Movement ± 7.5%. Tested acc. EN 1366-4 and classified acc. EN 13501-2/EAD 350141-00-1106.
Sealant | Configuration | Joint width (mm) | Joint depth (mm) | Resistance Class |
---|
SikaHyflex-250 Facade | 1 | 7 - 51 | 0.5 x width | EI 240 |
2 | 7 - 51 | 0.5 x width | EI 180, E 240 |
3 | 7 - 51 | 0.5 x width | EI 120, E 240 |
Sikaflex AT Connection | 1 | 7 - 51 | 0.5 x width | EI 240 |
2 | 7 - 51 | 0.5 x width | EI 180, E 240 |
3 | 7 - 51 | 0.5 x width | EI 180, E 240 |
Sikaflex PRO-3 | 2 | 7 - 51 | 0.5 x width | EI 180, E 240 |
3 | 7 - 51 | 0.5 x width | EI 45, E 120 |
*Brickwork, concrete or aerated concrete with a density ≥ 760 kg/m2
Resistance to fire of horizontal linear seals in rigid walls*
(wall thickness ≥ 150 mm) sealed with Sika Backer Rod Fire combined with SikaHyflex-250 Facade, Sikaflex AT Connection. Tested acc. EN 1366-4 and classified acc. EN 13501-2/EAD 350141-00-116.
Sealant | Configuration | Joint width (mm) | Joint depth (mm) | Resistance Class |
---|
SikaHyflex-250 Facade | 2 | 7 - 51 | 0.5 x width | EI 240 |
3 | 7 - 51 | 0.5 x width | EI 90, E 180 |
Sikaflex AT Connection | 2 | 7 - 51 | 0.5 x width | EI 240 |
3 | 7 - 51 | 0.5 x width | EI 120, E 240 |
*Brickwork, concrete or aerated concrete with a density ≥ 760 kg/m2
Resistance to fire of linear joints in rigid floors*
(floor thickness ≥ 200 mm) sealed with Sika Backer Rod Fire combined with SikaHyflex-250 Facade**, Sikaflex AT Connection** or Sikaflex PRO-3. Movement ± 7.5%. Tested acc. EN 1366-4 and classi- fied acc. EN 13501-2/EAD 350141-00-1106.
Sealant | Configuration | Joint width (mm) | Joint depth (mm) | Resistance Class |
---|
Sikaflex PRO-3 | 1 | 7 - 51 | 0.8 x width | EI 240 |
2 | 7 - 51 | 0.8 x width | EI 240 |
3 | 7 - 51 | 0.8 x width | EI 60, E 240 |
SikaHyflex-250 Facade | 1** | 7 - 51 | 0.8 x width | EI 240 |
2** | 7 - 51 | 0.8 x width | EI 240 |
3 | 7 - 51 | 0.8 x width | EI 120, E 180 |
Sikaflex AT Connection | 1** | 7 - 51 | 0.8 x width | EI 240 |
2** | 7 - 51 | 0.8 x width | EI 240 |
3 | 7 - 51 | 0.8 x width | EI 120, E 180 |
* Brickwork, concrete or aerated concrete with a density ≥ 760 kg/m3
** Not approved for pedestrian walkways acc. EN 15651-4 in the European Union
Further Documents
Limitations
- Sika Backer Rod Fire must be used in combination with SikaHyflex-250 Facade or Sikaflex AT Connection
- Limitations regarding dimensions and configuration described in the EN 13501-2 classification report and/or ETA 17/0980 must be respected
- Sika Backer Rod Fire shall be used by professional applicators only
IMPORTANT FIRE PRODUCTS NOTICE: The information displayed on this website should be used as a guide ONLY and our Technical Department should be contacted to obtain a tailored specification and any advice necessary before you place an order for fire protection products. Fire protection products are non-returnable except in accordance with Condition 8 of the Terms and Conditions and should be applied only by an individual with the necessary expertise and experience. We will not be held liable for any resulting damage to property, human life or monetary costs incurred due to the incorrect specification you have prepared or use of fire protection products caused by your negligence, including your failure to have contacted us to obtain the relevant advice/specification.