PPG SigmaGuard CSF 650

    7443
    PPG4179

    PPG SigmaGuard CSF 650 (also known as Amercoat CSF 650), is a two-component, solvent-free, amine-cured epoxy tank coating for crude oil/ballast and aliphatic petroleum products, with one-coat protection for steel structures, ships and storage tanks with excellent corrosion resistance.

    • Also suitable as a coating system for the storage and transportation of drinking water
    • Good resistance to various chemicals - Excellent resistance to crude oil up to 60°C (140°F)
    • Can be applied by heavy-duty, single-feed, airless spray equipment (60:1)
    • Reduced explosion risk and fire hazard - Good visibility due to light colour
    • Can be reinforced with chopped glass fibre or matt
    • Meets the requirements of EI 1541 (coating systems for aviation fuel storage tanks and pipes)

    Colour
    Size
    Finish

    £561.72 (incl. VAT)

    £468.10 (ex. VAT)

    Quantity
    Please choose your colour
    Available for Delivery (See Delivery Options Below)

    Description

    PPG SigmaGuard CSF 650 (also known as Amercoat CSF 650), is a two-component, solvent-free, amine-cured epoxy tank coating for crude oil/ballast and aliphatic petroleum products with one-coat protection for steel structures, ships and storage tanks with excellent corrosion resistance. Excellent resistance to crude oil up to 60°C (140°F), the coating meets the requirements of EI 1541 (coating systems for aviation fuel storage tanks and pipes).

    SigmaGuard CSF 650 is also suitable as a coating system for the storage and transportation of drinking water.



    Features & Benefits


    • Tank coating for crude oil/ballast and aliphatic petroleum products
    • Also suitable as a coating system for the storage and transportation of drinking water
    • Good resistance to various chemicals
    • One-coat protection for steel structures, ships and storage tanks with excellent corrosion resistance
    • Can be applied by heavy-duty, single-feed, airless spray equipment (60:1)
    • Reduced explosion risk and fire hazard
    • Good visibility due to light colour
    • Can be reinforced with chopped glass fibre or mat
    • A clear version is available for application of glass mats repair systems or application of chopped glass fibres
      • Contact our customer services (0113 2455450) for more information
    • Meets the requirements of EI 1541 (coating systems for aviation fuel storage tanks and pipes)
    • Excellent resistance to crude oil up to 60°C (140°F)

     

    ReferenceColourSizeGloss Level
    179130Green4 litresGloss
    179131Green20 litresGloss
    -Off-White20 litresGloss

    More colours may be available, depending on order quantity; contact our sales team on 0113 2455450 or [email protected] to discuss your requirements.



    Product Data


    Two-component, solvent-free, amine-cured epoxy coating

    Data for mixed product at 20°C (68°F)
    Number of componentsTwo
    Mass density1.3 kg/l (10.8 lb/US gal)
    Volume solids100%
    VOC (Supplied)Directive 1999/13/EC, SED: max. 109.0 g/kg
    max. 143.0 g/l (approx. 1.2 lb/US gal)
    EPA Method 24: 120.0 g/ltr (1.0 lb/USgal)
    Recommended dry film thickness300 - 600 µm (12.0 - 24.0 mils) depending on system
    Theoretical spreading rate3.3 m²/l for 300 µm (134 ft²/US gal for 12.0 mils)
    Pot life1 hour at 20°C (68°F)
    Dry to touch8 hours
    Overcoating IntervalMinimum: 24 hours
    Maximum: 20 days
    Full cure after5 days
    Shelf lifeBase: at least 24 months when stored cool and dry
    Hardener: at least 24 months when stored cool and dry

    Notes:

    • Refer below for more details on spreading rate and film thickness, overcoating intervals and curing times



    Surface Preparation


    Recommended Substrate Conditions and Temperatures

    Substrate conditions

    • Steel; blast cleaned to ISO-Sa2½, blasting profile 50 – 100 µm (2.0 – 4.0 mils)
    • Suitable primer; SIGMAGUARD 260, SIGMACOVER 280, SIGMAPRIME series or SIGMACOVER 522, depending on system requirements
    • Steel; power tooling to ISO-St3 for small and isolated areas (like repairs and joint welds) in fresh water and potable water tanks where spot blasting might be impractical

     

    Substrate Temperature & Application Conditions


    • Substrate temperature during application should be above 5°C (41°F)
    • Substrate temperature during application should be at least 3°C (5°F) above dew point



    System Specification


    • SIGMAGUARD CSF 650: 1 x 300 µm (12.0 mils); or a suitable primer of 50 µm (2.0 mils) + SIGMAGUARD CSF 650: 1 x 250 µm (10.0 mils)



    Application


    Instructions for Use

    Mixing ratio by volume: base to hardener 80:20 (4:1)

    • At lower temperature, the viscosity will be too high for spray application
    • The temperature of the mixed base and hardener should preferably be at least 20°C (68°F)
    • No thinner should be added
    • For recommended application instructions, see working procedure

     

    Induction Time


    • None.

     

    Airless spray


    • Use heavy-duty, single-feed, airless spray equipment, preferably 60:1 pump ratio and suitable high-pressure hoses
    • In-line heating or insulated hoses may be necessary to avoid cooling down of paint in hoses at low air temperature
    • Application with 45:1 airless spray equipment is possible, provided in-line, heated high-pressure hoses are used
    • Length of hoses should be as short as possible

    Recommended thinner

    • No thinner should be added

    Nozzle orifice

    • Approx. 0.64 mm (0.025 in)

    Nozzle pressure

    At 20°C (68°F) paint temperature min. 28.0 MPa (approx. 280 bar; 4061 p.s.i.). At 30°C (86°F) min. 22.0 MPa (approx. 220 bar; 3191 p.s.i.)

    Note:

    In case of using 45:1 airless spray equipment, the paint must be heated to approximately 30°C (86°F) in order to obtain the right application viscosity

     

    Brush/roller


    Recommended thinner

    • For stripe coating and spot repair only, no thinner should be added

     

    Cleaning Solvent


    Note:

    All application equipment must be cleaned immediately after use. Paint inside the spraying equipment must be removed before the pot life has been expired.



    Spreading Rate and Film Thickness


    DFTTheoretical spreading rate
    250 µm (10.0 mils)4.0 m²/l (160 ft²/US gal)
    300 µm (12.0 mils)3.3 m²/l (134 ft²/US gal)
    600 µm (24.0 mils)1.7 m²/l (67 ft²/US gal)

    Note:

    • Maximum DFT when brushing: 200 µm (8.0 mils)

     

    Measuring wet film thickness

    • A difference is often obtained between the measured apparent WFT and the real applied WFT. This is due to the thixotropy and the surface tension of the paint, which retards the release of air, trapped in the paint film for some time
    • A practical recommendation is to apply a WFT, which is equal to the specified DFT plus 60 µm (2.4 mils)

     

    Measuring dry film thickness

    • Because of low initial hardness the DFT cannot be measured within some days, due to the penetration of the measuring device into the soft paint film
    • The DFT should be measured using a calibration foil of known thickness placed in between the coating and the measuring device

     

    Overcoating interval for DFT up to 300 µm (12.0 mils)


    Overcoating with...Interval5°C (41°F)10°C (50°F)20°C (68°F)30°C (86°F)40°C (104°F)
    ItselfMinimum3.5 days36 hours24 hours16 hours12 hours
    Maximum20 days20 days20 days14 days7 days

    Notes:

    • Surface should be dry and free from any contamination

     

    Curing time for DFT up to 300 µm (12.0 mils)


    Substrate temperatureDry to handleFull cure
    5°C (41°F)60 hours15 days
    10°C (50°F)30 hours7 days
    20°C (68°F)16 hours5 days
    30°C (86°F)10 hours3 days
    40°C (104°F)8 hours48 hours

    Notes:

    • Adequate ventilation must be maintained during application and curing (please refer to information sheets information sheet 1433 and Directives for Ventilation Practice (information sheet 1434)
    • For drinking water tanks, a tank wash should be carried out after full cure and before the tank goes into service
    • When used as coating system for storage and transport of drinking water the recommended working and washing procedure should be followed:

     

    Washing procedures

    • The recommended washing procedure must be applied after completion of the application.
    • Sufficient time for full-curing and ventilation must be allowed in accordance with the recommendations as stated in the latest Product Data Sheets and working procedure.
    • Always an adequate washing procedure should be followed.
    • Several adequate washing procedures are available and may be used (see e.g. washing procedure described in relevant certificate).

     

    Example 1: Adequate washing procedure

    • After full curing of the system as per the latest PDS, the tank should be filled completely with fresh tap water
    • The fresh tap water should remain in the tanks at least 4 full days
    • Afterwards all tank compartments such as inner hull sides, bottom and deck-heads etc. should be thoroughly washed using high pressure water
    • After washing, the tanks should be thoroughly drained
    • After this procedure the tanks will be fit to carry drinking water

     

    Example 2: Adequate washing procedure

    • All personnel should wear watertight suits, boots and gloves properly cleaned with a sodium hypochlorite solution (1% active chlorine per litre)
    • All tank sides, bottom and deckheads etc. should be brush cleaned or high-pressure spray cleaned with 1% active chlorine solution as above|note: this can also be done by butterworth washing
    • All parts should be high pressure cleaned with tap water and tanks drained
    • Concentrated active chlorine solution should be sprinkled on bottom; approx. 1 litre per 10 m² (1 quart per 100 ft²)
    • Tanks should be filled with tap water to a depth of approx. 20 cm (8 inches) and the water should remain in the tank for at least 2 hours (max. 24 hours)
    • Tanks should be thoroughly flushed out with tap water
    • Depending upon local regulations it may be necessary to take water samples, after filling tank completely, to check on bacteria
    • After this procedure the tanks will be fit to carry drinking water

     

    Pot Life (at application viscosity)


    Mixed product temperaturePot life
    20°C (68°F)1 hour
    30°C (86°F)45 minutes
    40°C (104°F)25 minutes

    Note:

    • Due to exothermic reaction, temperature during and after mixing may increase

     



    Disclaimer


    • SIGMAGUARD CSF 650 is approved for purpose in accordance with the requirements of the relevant certificate
    • Rawlins Paints & PPG Protective & Marine Coatings does not accept any responsibility or liability for any odour, taste or contamination imparted to the drinking water from the coatings or products retained in the coating



    Safety Precautions


    • For paint and recommended thinners, see information sheets information sheet 1430, information sheet 1431 and the relevant Material Safety Data Sheets in the attachments section above
    • Although this is a solvent-free paint, care should be taken to avoid inhalation of spray mist, as well as contact between the wet paint and exposed skin or eyes
    • If workers are exposed to concentrations above the exposure limit, they must use appropriate personal protective equipment (PPE)
    • Ventilation should be provided in confined spaces to maintain good visibility



    References


    Product Details
    4179-552170

    Data sheet

    Manufacturer
    PPG
    For Use On
    Steel
    Application Method
    Brush, Roller, Spray
    Sheen
    Gloss
    Colour
    Standard / Ready Mixed
    VOC Levels
    Low (50-149 g/l)
    Single, Two or Three Pack
    Two-Pack
    Product Certifications
    Meets the requirements of EI 1541 2.2 (coating systems for aviation fuel storage tanks and pipes)
    Pack Size
    4L, 20L
    Parts
    Two
    Base Type
    Solvent-borne
    Solvent
    Epoxy
    Mixing Ratio
    4:1
    Suitable Substrates
    Steel
    Key Features
    For crude oil/ballast and aliphatic petroleum products, with one-coat protection for steel structures, ships and storage tanks with excellent corrosion resistance.
    Application
    Brush, Roller, Spray
    Touch Dry (at 20°C)
    8 hours
    Dry to Handle (at 20°C)
    16 hours
    Dry to Recoat (at 20°C)
    24 hours
    Fully Cured (at 20°C)
    5 days
    Pot Life (at 20°C)
    1 hour
    Coverage
    3.3 m²/l for 300 µm (134 ft²/US gal for 12.0 mils)
    Recommended Thinner/Cleaner
    90-83 or 90-53
    Unit Contents
    Base & hardener
    Compatible Primers
    SIGMAGUARD 260, SIGMACOVER 280, SIGMAPRIME series or SIGMACOVER 522, depending on system requirements
    Compatible Topcoats
    -
    Max. Application Temperature
    -
    Min. Application Temperature
    5°C (41°F)
    Density
    1.3 kg/l (10.8 lb/US gal)
    Solids by Volume
    100%
    VOC
    Directive 1999/13/EC, SED: max. 109.0 g/kg max. 143.0 g/l; EPA Method 24: 120.0 g/ltr
    Shelf Life (from date of manufacture)
    Base & hardener: at least 24 months
    UN Number (Activator)
    UN3470
    UN Number (Base)
    UN3082
    Base Type
    Solvent Free
    Suitable For Use On
    Steel
    Finish
    Gloss
    Application Method
    Brush
    Application Method
    Spray
    Application Method
    Roller
    Product Usage Type
    Tank Coating
    Product Range
    SigmaGuard
    Colour Family
    Green
    Attachments
    Download


    Customer agrees that before placing an Order, Customer has read and understood the most up to date Product Data Sheet for the Product. Where we have access to the Product Data Sheet from the manufacturer, we will either provide a copy on request, or include a link to the Product Data Sheet available on the manufacturer’s website. Customer further agrees that we have no liability for any errors or omissions contained within the Product Data Sheets. For more information, please see our Terms & Conditions of Sale.


    Be the first to ask a question about this product!


    Question about the product

    * Required fields
    (read)
    Send

    IMPORTANT SHIPPING & DELIVERY INFORMATION

    PPG SigmaGuard CSF 650 is only available with the shipping and delivery timescales listed below - please do not contact our Customer Support Team with enquiries about alternative or earlier shipping and delivery times.

    Saturdays and Sundays, as well as Bank Holidays, are not classed as working days.

    Orders placed after the cut-off for this product will not be processed for earliest dispatch until 9am the next working day.

    All delivery costs below are excluding VAT


    You might also like

    PPG Thinner 90-53

    This thinner has been developed by PPG Protective and Marine Coatings for use with selected paint products.More Information Delivery Info

    Price £35.49 (ex. VAT)

    £42.59 (incl. VAT)

    £35.49 (ex. VAT)

    In Stock and Available for Delivery

    PPG Thinner 90-83

    This thinner has been developed by PPG Protective and Marine Coatings for use with selected paint products.More Information Delivery Info

    Price £111.74 (ex. VAT)

    £134.09 (incl. VAT)

    £111.74 (ex. VAT)

    In Stock and Available for Delivery

    PPG SigmaCover 280

    SigmaCover 280, a universal epoxy anticorrosive primer suitable for ballast tanks, decks, topside, superstructure, hull and cargo oil tanks. SigmaCover 280 is used in protective coating systems for steel and non-ferrous metals, curing at temperatures down to 5°C (41°F), and can be overcoated with most alkyd, chlorinated rubber, vinyl, epoxy...

    Price £36.24 (ex. VAT)

    £43.49 (incl. VAT)

    £36.24 (ex. VAT)

    In Stock and Available for Delivery

    PPG SigmaCover 522

    PPG SigmaCover 522 is a two-component, micaceous iron oxide-pigmented, polyamide-cured epoxy primer/sealer/coating. It has excellent adhesion to, and sealing of, weathered, cleaned, zinc-rich primers and metal-sprayed steel, with good adhesion to properly pre-treated galvanized steel.Can be used in systems for atmospheric or water-immersed...

    Price £277.84 (ex. VAT)

    £333.41 (incl. VAT)

    £277.84 (ex. VAT)

    In Stock and Available for Delivery

    Surface Preparation Kits for Steel

    These surface preparation kits for steel have been created to help provide customers with an easily accessible bundle of tools to aid in the preparation of steel surfaces in accordance with ISO 8501-1 (St2/3) and SSPC (SP 2/3). Please click here for important information about these kits. Kit Contents: SET 1 (Hand Tools)1 x Rust-Oleum...

    Price £21.53 (ex. VAT)

    £25.84 (incl. VAT)

    £21.53 (ex. VAT)

    In Stock and Available for Delivery